A Numerical Evaluation of Insulated CFRP-Strengthened RC Beams Exposed to Fire

Article Preview

Abstract:

There are mainly two approaches to improve the fire resistance of FRP systems. While the most common way is to protect or insulate the FRP systems, the other way is to use fibers and resins with better fire-performance. In this paper a numerical investigation for evaluating the fire behavior of insulated CFRP-strengthened RC beams is presented.The effects of external loading and thermal expansion of materials in both the structural and the thermal behavior of composite elements due to loading and elevated temperatures are taken into consideration in a finite element model. The validity of the numerical model isdemonstrated withthe results from an existing experimental study on insulated CFRP-strengthened RC beam. The conclusions of this investigation have been employed to predict the structural behavior of concrete structures successfully.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

62-69

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] V.K.R. Kodur and A. Ahmed: J. Compos. Constr. Vol. 14 (2010), p.730.

Google Scholar

[2] J. G. Dai, W. Y. Gao and J. G. Teng: In L. Ye, Q. Yue and P. Feng, Eds.: Proceedings of The5th Int. Conference on Advance in FRP Composites in Civil Engineering, CICE 2010.(Beijing, China, 2010).

DOI: 10.1007/978-3-642-17487-2

Google Scholar

[3] American Concrete Institute (ACI): Guide for the design and construction of externally bondedFRP systems for strengthening concrete structures, ACI 440.2R-08, ACI Committee 440, (Farmington Hills, Mich, 2008).

DOI: 10.14359/51700867

Google Scholar

[4] H. Blontrock, L. Taerwe and S. Matthys: ACI, Special Publication Vol. 188 (1999), p.43.

Google Scholar

[5] B. Williams, L. A. Bisby, V. K. R. Kodur, M. F. Green and E. Chowdhury: Compos. Part A-Appl. S. Vol. 37 (2006), p.1151.

Google Scholar

[6] L. A. Bisby, V. K. R. Kodur and M. F. Green: ACI Struct. J. Vol. 102 (2005), p.883.

Google Scholar

[7] W. Y. Gao, K. X. Hu and Z. D. Lu: China Civil Eng. J. Vol. 43 (2010), p.15.

Google Scholar

[8] B. Williams, V. K. R. Kodur, M. F. Green and L. Bisby: J.ACI Struct. Vol.105 (2008), p.60.

Google Scholar

[9] L. A. Bisby, M. F. Green and V. K. R. Kodur: J. Compos. Constr. Vol. 9 (2005), p.15.

Google Scholar

[10] R. A. Hawileh, M. Naser, W. Zaidan and H. A. Rasheed: Eng.Struct. Vol. 31 (2009), p.3072.

Google Scholar

[11] M. Deuring: Brandversucheannachtralichverstarktentagernausbeton.Research ReportEMPA No. 148'795 Swiss Federal Laboratories for Materials Testing and Research, (Dubendorf,1994), p.97.

Google Scholar

[12] H. Blontrock, L. Taerwe and P. Vandevelde: In K. Bergmeister, Ed.: Proceedings of the 3rd International PhD Symposium in Civil Engineering. (Vienna, Austria, 2000), Vol.2, p.151.

Google Scholar

[13] H. Blontrock, L. Taerwe and P. Vandevelde: In C. J. Burgoyne, Ed.: Proceedings of 5th Int.Conference on Fibre Reinforced Plastics for Reinforced Concrete Structures, FRPRSC-5.(Telford, Cambridge, UK, 2001), p.547.

Google Scholar

[14] D. B. Tann: Proceedings of Composites Processing Association Annual Conference. FRP strengthened concrete elements in fire, (Pontyclun, UK, 2004).

Google Scholar

[15] K. H. Tan and Y. Zhou: J. Compos. Constr. Vol. 15 (2011), p.304.

Google Scholar

[16] G. A. Khoury: Progress in Struct. Eng.Mater. Vol. 2 (2000), p.429.

Google Scholar

[17] R. A. Hawileh, M. Naser, W. Zaidanand H.A. Rasheed: Eng. Struct. Vol. 31 (2009), p.3072.

Google Scholar

[18] R. Barnes and J. Fidell: J. Compos. Constr. Vol.10 (2006), p.503.

Google Scholar

[19] W. Y. Gao, K. X. Hu and Z. D. Lu: In. M. G. Alexander, H. D.Beushausen, F. Dehn and P. Moyo, Eds.: 2nd International Conference onConcrete Repair, Rehabilitation and Retrofitting,ICCRRR-2. (Cape Down, South Africa,2008), p.1217.

DOI: 10.1201/9781439828403

Google Scholar

[20] ANSYS Workbench, Version 14.5. ANSYS Inc. (Canonsburg, PA, 2012).

Google Scholar

[21] J. P. Firmo, J. R. Correia and P. França: Compos. Part B-Eng. Vol. 43 (2012), p.1545.

Google Scholar

[22] ISO 834, Fire resistance tests: Elements of building construction. Genève: ISO; 1975.

Google Scholar