Learning from Case Studies: Timber Tower of Gospić Cathedral and Traditional Timber Church

Article Preview

Abstract:

The conservation of historical timber structures requires both the knowledge of structural behavior of complete building and behavior of any single element in structure. Because of a poor communication between the institutions involved in the conservation and restoration of buildings and institutions that urgently require renovation of structures, renovation of historic buildings is often performed inappropriately due to engineering and architectural approach. Buildings are frequently subjected to inappropriate interventions, replacements of structural elements, or even worse, they are demolished. First case study in this paper is Cathedral from Gospic city which was subjected to inappropriate reconstruction in 1990s. Second case study is small traditionally constructed timber chapel in village Lijevi Stefanki which represents a valuable monument of rural cultural heritage.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

927-934

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] V. Rajčić, D. Čizmar, M. Stepinac, Static design and strengthening of the Virgin Marry Cathedral structure, Faculty of Civil Engineering, Zagreb, (2008).

Google Scholar

[2] V. Rajčić, A. Bjelanović, Timber structures according to European norms, Croatian University Publishers, Zagreb, (2007).

Google Scholar

[3] Đ. Peulić, Structural elements of the buildings, second ed., Školska knjiga, Zagreb (1986).

Google Scholar

[4] V. Rajčić, D. Čizmar, M. Stepinac, Report: current state of structure of the Chapel in Lijevi Štefanki, Faculty of Civil Engineering, Zagreb, (2013).

Google Scholar

[5] P.B. Laurenco: Assessment, diagnosis and strengthening of Outeiro Church, Portugal, Construction and Building Materials, Elsevier, 19 (2005) 634–645, (2005).

DOI: 10.1016/j.conbuildmat.2005.01.010

Google Scholar

[6] EN 338, 2009, Structural timber - strength classes. Comité Européen de Normalisation (CEN), Brussels, Belgium, (2009).

Google Scholar

[7] EN 1995-1-1, 2004. Eurocode 5, Design of timber structures - part 1-1: General -common rules and rules for buildings. Comité Européen de Normalisation (CEN), Brussels, Belgium, (2004).

DOI: 10.3403/03174906

Google Scholar

[8] P. B. Laurenco , A.O. Feio, J.S. Machado, Chestnut wood in compression perpendicular to the grain: Non-destructive correlations for test results in new and old wood, Construction and Building Materials 21 (2007) 1617–1627, Elsevier.

DOI: 10.1016/j.conbuildmat.2006.07.011

Google Scholar

[9] C. Calderoni, G. De Matteis, C. Giubileo, F.M. Mazzolani, Flexural and shear behaviour of ancient wooden beams: Experimental and theoretical evaluation, Engineering Structures 28 (2006) 729–744.

DOI: 10.1016/j.engstruct.2005.09.027

Google Scholar

[10] C. Calderoni, G. De Matteis , C. Giubileo, F.M. Mazzolani, Experimental correlations between destructive and non-destructive tests on ancient timber elements, Engineering Structures 32 (2010), 442 -448.

DOI: 10.1016/j.engstruct.2009.10.006

Google Scholar

[11] B. Kasal, RILEM TC 215 AST "In-situ assessment of structural timber, RILEM Symposium on On Site Assessment of Concrete, Masonry and Timber Structures - SACoMaTiS 2008, Conference Proceedings, RILEM Publications SARL, 2008, p.1033 – 1037.

DOI: 10.1007/978-94-007-0560-9

Google Scholar