Abstract:

One of the main objectives of this study was to activate the pozzolanic activity of sludge, produced by municipal sewage treatment plants (MSTP), make it become an admixture to replace a part of cement in concrete. Nowadays, a significant quantity of MSTP sludge is obtained in China. That is why this paper examines the possibility of adding this waste product to plain concrete with Portland cement. Preliminary studies are carried out on using MSTP sludge as an admixture by thermal (calcining) and mechanical (grinding) treatment. The pozzolanic activity of the calcined sludge ash (CSA) evaluated by Cement Mortar test. The CSA-blended cement concrete was formed into specimens of cubic concrete with 100 mm×100 mm×100 mm. They are with 30 wt. % cement replaced by CSA, which was prepared by the optimal activation conditions. The Cement Mortar test results revealed that the optimal activation conditions of CSA were as follows: calcined at 800°C for 2.5 hours followed by fast cooling in air and then ground until 60 minutes. Besides, the compressive strengths of concrete specimens with added 30% CSA were 103.6% and 105.3% of those of the ordinary Portland cement concrete specimens at 7 and 28 days, respectively. These results demonstrate the feasibility of recycling MSTP sludge as an admixture in concrete for construction engineering.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 785-786)

Pages:

308-316

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Weidong Li, Ming Li, Weifeng Li and Haifeng Liu: Fuel Vol. 89 (2010), pp.1566-1572.

Google Scholar

[2] Alina S, Maria S and Ola H: Bioresour Technol Vol. 100 (2009), p.3497–505.

Google Scholar

[3] Walid BA, Noureddine G, Abdelbasset L, Gijs DL, Marc V and Naceur J, et al: Agric Ecosyst Environ Vol. 130 (2009), p.156–63.

Google Scholar

[4] Conesa JA, Marcilla A, Prats D and Pastor MR: Waste Manage Res Vol. 15 (1997), p.293–305.

Google Scholar

[5] Konar SM, Boocock DGB, Mao V, Liu J: Fuel Vol. 73 (1994), p.642–646.

Google Scholar

[6] Ferrasse JH, Seyssiecq I and Roche N: Chem Eng Technol Vol. 26 (2003), p.941–945.

Google Scholar

[7] S. Valls, A. Yagüe, E. Vázquez and C. Mariscal: Cement and Concrete Research, Vol. 34 (2004), pp.2203-2208.

DOI: 10.1016/j.cemconres.2004.02.004

Google Scholar

[8] Rui Yu, Qing Ye and Wen Ye: China Water & Wastewater Vol. 20 (2004), pp.1-5 [In Chinese].

Google Scholar

[9] M. Uysal, K. Yilmaz: Cem Concr Compos Vol. 33 (2011), p.771–776.

Google Scholar

[10] Vizcayno C, de Gutiérrez RM, Castello R, Rodriguez E and Guerrero CE: Applied Clay Science Vol (2010), pp.405-413.

DOI: 10.1016/j.clay.2009.09.008

Google Scholar

[11] GB/T14684-2001: Standard for Sand for building, National standard of the P.R. China; 2001[In Chinese].

Google Scholar

[12] P.K. Mehta, P.J.M. Monteiro: Concrete: Microstructure, Properties, and Materials (McGraw-Hill, New York 2006).

Google Scholar

[13] Dong OuYang, Cheng Bo Yi, WeiTing Xu and LiuLei Lu: Advanced Materials Research Vol. 194 (2011), pp.2119-2126.

Google Scholar

[14] Pan Pan, Dong OuYang, ChengBo Yi, Bo Ning, Liulei Lu and TingTing Wu: China Concrete and Cement Products (2011), pp.53-55 [In Chinese].

Google Scholar

[15] GB175-2007: Standard for Common Portland cement, National standard of the P.R. China; 2007 [In Chinese].

Google Scholar

[16] GB/T 18046-2008: Standard for Ground granulated blast furnace slag used for cement and concrete, National standard of the P.R. China; 2008[In Chinese].

Google Scholar

[17] GB/T 17671-1999: Method of testing cements-Determination of strength, National standard of the P.R. China; 1999 [In Chinese].

Google Scholar

[18] GB/T 50080-2002: Standard for test method of performance on ordinary fresh concrete, National standard of the P.R. China; 2002[In Chinese].

Google Scholar

[19] GB/T 50081–2002: Standard for test method of mechanical properties on ordinary concrete, National standard of the P.R. China; 2002[In Chinese].

Google Scholar

[20] Husillos Rodríguez N, Martínez-Ramírez S and Blanco-Varela MT, et al: Cem Concr Compos Vol. 33 (2011) , p.267–75.

Google Scholar

[21] Sheng Su, Peisheng Li, Xuexin Sun and Song Hu: Thermal Power Generation Vol. 9 (2004), p: 69-74 [In Chinese].

Google Scholar

[23] Sahmaran M, Christianto HA, Yaman IO: Cem Concr Comp Vol. 28 (2006), 432–440.

Google Scholar

[24] V.G. Papadakis, S. Tsimas: Cement and Concrete Research Vol. 32 (2002), p.1525 –1532.

Google Scholar