Analysis on Residual Capacity of Steel after High Temperature

Article Preview

Abstract:

Steel material is very sensitive to temperature, the physical and mechanical properties at high temperature are distinct with those at room temperature. Taking steel beams as the research objects, based on EUROCODE3 for the steel properties at high temperature, this paper established numerical models and analyzed the carrying capacity of steel beams under different temperatures. According to the analysis, it is concluded that the higher the temperature, the lower the subsequent carrying capacity of the steel beam, and the formulas between them are defined by fitting the data.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

322-327

Citation:

Online since:

October 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] NEN-EN 1993-1-2. (2005) Eurocode 3: Design of Steel Structures-Part 1-2: General Rules-Structural Fire Design. Brussels: European Committee for Standardization.

DOI: 10.1002/9783433601570.oth1

Google Scholar

[2] Richard Liew, J. Y. (2008) Survivability of Steel Frame Structures Subject to Blast and Fire. Journal of Constructional Steel Research, Vol. 64 (7-8), pp.854-866.

DOI: 10.1016/j.jcsr.2007.12.013

Google Scholar

[3] Wong, M. B. (2006) Effect of Torsion on Limiting Temperature of Steel Structures in Fire. Journal of Structural Engineering, Vol. 132 (5), pp.726-732.

DOI: 10.1061/(asce)0733-9445(2006)132:5(726)

Google Scholar

[4] Lopes, N., Vila Real, P., Simoes da Silva, L. et al. (2012) Numerical Analysis of Stainless Steel Beam-Columns in Case of Fire. Fire Safety Journal, Vol. 50, pp.35-50.

DOI: 10.1016/j.firesaf.2012.02.003

Google Scholar

[5] Pakala, P., Kodur, V., Selamet, S. et al. (2012) Fire Behavior of Shear Angle Connections in a Restrained Steel Frame. Journal of Constructional Steel Research, Vol. 77, pp.119-130.

DOI: 10.1016/j.jcsr.2012.05.006

Google Scholar

[6] Elsawaf, S., Wang, Y.C. (2013) Behaviour of restrained structural subassemblies of steel beam to CFT column in fire during cooling stage. Engineering Structures, Vol. 46, pp.471-492.

DOI: 10.1016/j.engstruct.2012.08.023

Google Scholar

[7] Yu, W., Zhao, J., Luo, H. et al. (2011) Experimental study on mechanical behavior of an impacted steel tubular T-joint in fire. Journal of Construction Steel Research, Vol. 67, pp.1376-1385.

DOI: 10.1016/j.jcsr.2011.03.001

Google Scholar

[8] Feng, M., Wang, Y.C. (2005) An Experimental Study of Loaded Full-Scale Cold-Formed Thin-Walled Steel Structural Panels under Fire Conditions. Fire Safety Journal, Vol. 40 (1), pp.43-63.

DOI: 10.1016/j.firesaf.2004.08.002

Google Scholar

[9] Chen, C., Zhang, W. (2011) Experimental study of the mechanical behavior of steel staggered truss system under pool fire conditions. Thin-Walled Structures, Vol. 49, pp.1442-1451.

DOI: 10.1016/j.tws.2011.07.004

Google Scholar