Research on Topology and its Performance of Grid-Connected Inverter for Direct-Driven Wind Power

Article Preview

Abstract:

It is necessary that the grid-connected inverter was set up in wind power, in order to convey energy generated in wind power to the grid. There are many sorts of inverters, but only two sorts of inverters suit wind power system, which are current-source inverter and voltage-source inverter, and only the later is being widely used. Their configuration, principle, control and characteristic were analyzed in this paper. Results have shown that, voltage-source grid-connected inverter has been the core of the commutation control configuration of direct-driven wind power, which is decided by the peculiarity of itself.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 846-847)

Pages:

701-705

Citation:

Online since:

November 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Bai Zhengui. The Design of DG Grid-connected Inverter and Research on Some Related Control Methods, " Master, s thesis, Zhejiang University, (2010).

Google Scholar

[2] Jiang Dapeng. The study on Grid-connected Inverters for distributed power system, " Master, s thesis, Zhejiang University, (2006).

Google Scholar

[3] Xu Po, et al. Small Wind Turbine Grid-Connected Systems Based on Z-Source Inverter[J], Transactions of China Electrotechnical Society, 2008, 23(4), pp.93-97.

Google Scholar

[4] Wu Tingting. The Control Strategies for Grid-connected Inverter in Distributed Power System, " Master's thesis, Chang, an University, (2007).

Google Scholar

[5] Yang Enxing. Research on Key Aspects in Power Converter for Direct-drive Low Speed PMSG Wind Generation System, PHD. Thesis, Zhejiang University, (2009).

Google Scholar

[6] Huang Ronggen, et al. Design and Analysis for H igh Inductance PM Wind Gengertor,Micromotors, 2011,43(7) , pp.17-24.

Google Scholar

[7] Mao Mei-qin, Xu Bin, Control for the Small Wind Turbing System Based on CSI, Power Electronics, 2011,45(8) , pp.78-80.

Google Scholar

[8] Xiao Lan, et al. Multi-Inverter Parallel System Applying Average Current Controlling Method[J], Proceedings of the Chinese Society for Electrical Engineering, 2008, 28(3), pp.77-82.

Google Scholar

[9] Liserre, et al. Stability improvements of an LCL-filter based three-phase active rectifier, Power Electronics Specialists Conference, 2002. PESC´02. 33th IEEE, pp.1195-1201.

DOI: 10.1109/psec.2002.1022338

Google Scholar

[10] Eric Wu et al. Digital Current Control of a Voltage Source Converter With Active Damping of LCL resonance, IEEE Trans. On Power Electronics, Vol. 21, Issue. 5, 2006, pp.1364-1373.

DOI: 10.1109/tpel.2006.880271

Google Scholar

[11] Haque,M. et al. A Novel Control Strategy for a Variable Speed Wind Turbine with a Pemanent Magnet Synchronous Generator, " Industry Application Society Annual Meeting, 2008. IAS, 08. IEEE. pp.1-8.

DOI: 10.1109/08ias.2008.374

Google Scholar