Study on Stability of Hydroelectric Generating Set Influenced by the Governor Parameters under Isolated Grid
Abstract:
In order to study on stability of hydroelectric generating set under isolated grid, taking hydraulic, mechanical, and electrical system into consideration to build the mathematical model. This paper has researched on the main governor parameters sensitivity in the small fluctuations transition process of complex hydropower station under isolated grid. According to the simulated results, KP or KI increases, or KD decreases appropriately, governor quality of small fluctuation transition process will be better. The influence caused by KD is the most obvious of the three.
Info:
Periodical:
Pages:
1799-1803