Research of Micro Airstream Gyroscope Sensitive Mechanism
Abstract:
The sensitive mechanism of micro airstream gyroscope was explained by calculating the distributing of stream field in the sense organ. According to the real size of micro airstream gyro-scope, ANSYS-FLOTRAN CFD was used to create models and work out the gas flow field and distributing in the two-dimensional chamber with different angular velocities. The results show that while the gyroscope in a static state the gas velocities at both hot-wires are equal as well as the current, and the output voltage is zero. On inputting an angular rate the gas velocities differ and a voltage signal proportional to the input angular rate is achieved.
Info:
Periodical:
Pages:
821-824
Citation:
Online since:
February 2014
Authors:
Price:
Сopyright:
© 2014 Trans Tech Publications Ltd. All Rights Reserved