Studies on the Effect of Altitude on the Flammable Liquids' Flash Point

Article Preview

Abstract:

Presented in this paper is part of an experimental series conducted at different altitudes to investigate the influence of altitude on the flammable liquids flash point. The BS-1 closed bomb apparatus is used to measure the flash points of two flammable liquids (dimethylacetylamide (DMA) and RP-5 Jet A) in a hypobaric chamber under the altitude change from 4860 km to the sea level. The experimental results show that the flash points of DMA and Jet A decrease linearly with the increase in altitude in the low altitude region below the corresponding critical altitudes but non-linearly above. The critical altitudes for DMA and RP-5 Jet A are found to be 3 km and 3.83 km respectively. When the altitude reaches or surpasses the critical altitude, the flash point decreases rapidly. In particular, the flash point of the DMA exhibits a peculiar sudden transition above the critical altitude.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

345-348

Citation:

Online since:

March 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] L. Nestor, Investigation of turbine fuel flammability within aircraft fuel tanks, Final Report DS-67-7, Naval Air Propulsion Test Center, Naval Base, Philadelphia, (1967).

Google Scholar

[2] J. J. Lee, And J. E., Shepherd, Spark Ignition Measurements in Jet A: part II, Explosion Dynamics Laboratory Report FM99-7, California Institute of Technology, (1999).

Google Scholar

[3] J.E. Shepherd, C.D. Nuyt, J.J. Lee, Flash Point and Chemical Composition of Aviation Kerosene (Jet A), FM99-4, Explosion Dynamics Laboratory, Pasadena, CA, (2000).

Google Scholar

[4] Y Tang, Y Niu, L Yin, D Zhou, J Wang, Experiment studies on the effect of altitude on Jet A's flash point, Fire and Materials, 2012, DOI: 10. 1002/fam. 2141.

DOI: 10.1002/fam.2141

Google Scholar

[5] Inspection and Quarantine of the People's Republic of China. Determination of flash point- Pensky-Martens closed cup method, GB/T261-2008, China Stand ards Press, Beijing, China, (2008).

DOI: 10.3403/02710440

Google Scholar

[6] NFPA30, Flammable and Combustible Liquids Code, Batterymarch Park, Quincy, MA, (2008).

Google Scholar

[7] Z. Li, Y. He, H. Zhang, J. Wang, Combustion Characteristics of n-Heptane and Wood Crib Fires at High Altitude, Proceedings of the Combustion Institute. 32 (2009) 2481-2488.

DOI: 10.1016/j.proci.2008.06.033

Google Scholar