[1]
Maldague X.P. Applications of infrared thermography. In: Nondestructive Evaluation, Terends in Optical Nondestrutive Testing (invited chapter), Pramod Rastogi Ed., pp.591-609, (2000).
DOI: 10.1016/b978-008043020-1/50040-5
Google Scholar
[2]
Maldague X.P. Theory and practice of infrared technology for nondestructive testing, Wiley & Sons, Inc., New York, (2001).
Google Scholar
[3]
Nondestructive Testing Handbook, Third Edition, Vol. 3 Infrared and Thermal Testing, Chap 15, ASNT, (2001).
Google Scholar
[4]
Rogalski A. Infrared detectors: an overview. Journal of Alloys and Compounds 2004, 371: 53–57.
Google Scholar
[5]
Meola C., Carlomagno G.M. Recent advances in the use of infrared Thermography. Institute of Physics Publishing Measurement Science and Technology 2004; 15: R27–R58.
DOI: 10.1088/0957-0233/15/9/r01
Google Scholar
[6]
Castanedo C.I.N., Avdelidis P., Grenier M., Maldague X.P. and Bendada A. Active thermography signal processing techniques for defect detection and characterization on composite materials, Proc. SPIE 7661, 76610O (2010); doi: 10. 1117/12. 850733.
DOI: 10.1117/12.850733
Google Scholar
[7]
Snell Jr J. R., Spring, R. W. Infrared Thermography Advances. Thermal NDT methods have continued to evolve with the advancements in thermal imaging and image processing. October 2, 2007. In NDT Magazine http: /www. ndtmag. com/Articles.
Google Scholar
[8]
Wiggenhauser H. Active IR applications in civil engineering. Infrared Physics & Technology 2002, 43; p.233–238.
DOI: 10.1016/s1350-4495(02)00145-7
Google Scholar
[9]
Meola C., Carlomagno G. M., Giorleo L. The use of infrared thermography for materials characterization. Journal of Materials Processing Technology 155–156 (2004) 1132–1137.
DOI: 10.1016/j.jmatprotec.2004.04.268
Google Scholar
[10]
Barreira, E., Freitas, V. P. Evaluation of building materials using infrared thermography. Construction and building materials, v. 21, p.218–224, (2007).
DOI: 10.1016/j.conbuildmat.2005.06.049
Google Scholar
[11]
Servais P, Gerlach N, Development of a NDT method using thermography for composite material inspection on aircraft using military thermal imager. V International Workshop, Advances in Signal Processing for Non Destructive Evaluation of Materials Québec City (Canada), 2-4 Aug. 2005, pp.197-202.
Google Scholar
[12]
Shepard S.M. Flash Thermography of Aerospace Composites. IV Conference Pan-American the NDT. Buenos Aires – October (2007).
Google Scholar
[13]
Maierhofer Ch., Brink A., Röllig M. and Wiggenhauser H. Transient thermography for structural investigation of concrete and composites in the near surface region Infrared Physics & Technology Volume 43, Issues 3-5, June 2002, Pages 271-278.
DOI: 10.1016/s1350-4495(02)00151-2
Google Scholar
[14]
Sun, J.G. Deemer, C., Ellingson, W.A., Easler, T.E., Szweda, A., Craig, P.A. [Publication In 24. international thermal conductivity conference, Pittsburgh, PA (United States), 26-29 Oct 1997; Other Information: PBD: Sep (1997).
DOI: 10.2172/554854
Google Scholar
[15]
Santulli C., Jeronimidis G, Measurement of surface void content on balsa wood using IRthermography, E-Journal of Non-Destructive Testing 11 n. 6, June (2006).
Google Scholar
[16]
Lee, S., Lee, JH., Park, IK., Song, S., Choi MY. Thermographic damage detection of ceramic matrix composites during tension testing. Journal Key Engineering Materials 2006. Volumes 321 – 323: 825-830.
DOI: 10.4028/www.scientific.net/kem.321-323.825
Google Scholar
[17]
Pan Y. P., Miller R.A., Chu T. P. and Filip P. Detection of defects. In commercial c/c composites using infrared thermography proceedings of the SEM Annual Conference June 1-4, 2009 Albuquerque New Mexico USA ©2009 Society for Experimental Mechanics Inc. Pp1-8.
Google Scholar
[18]
Grinzato, E., Vavilov, V., Kauppinem, T. Quantitative infrared thermography in buildings. Energy and Buildings, v. 29 (1998) pp.1-9.
DOI: 10.1016/s0378-7788(97)00039-x
Google Scholar
[19]
Balaras, C.A., Argiriou, A.A. Infrared thermography for building diagnostics. Energy and Buildings, v. 34 (2002) pp.171-183.
DOI: 10.1016/s0378-7788(01)00105-0
Google Scholar
[20]
Avdelidis, N.P., Moropoulou, A. Emissivity considerations in building thermography. Energy and Buildings, v. 35 (2003) pp.663-667.
DOI: 10.1016/s0378-7788(02)00210-4
Google Scholar
[21]
Clark MR, McCann DM, Forde MC. Application of infrared thermography to the non-destructive testing of concrete and masonry bridges. NDT & E International Independent Nondestructive Testing and Evaluation 2003; 36 (4): 265-275.
DOI: 10.1016/s0963-8695(02)00060-9
Google Scholar
[22]
Ocaña, S.M., Guerreo, I.C., Requena, I.G. Evaluation of buildings materials using infrared thermography. Energy and Buildings, v. 36 (2004) pp.515-523.
Google Scholar
[23]
Nahant M., Paez S., Leeuwen J. V. Detection by infrared thermography of the heat signature of diseases and defects in concrete structures of civil engineering. 10th International Conference on Quantitative InfraRed Thermography July 27-30, 2010, Québec (Canada).
DOI: 10.21611/qirt.2010.099
Google Scholar
[24]
Grinzato E., Cadelano G., Bison P., Peron F. and Maldague X. High resolution and automatic survey of buildings by IR thermography 10th International Conference on Quantitative Infrared Thermography July 27-30, 2010, Québec (Canada).
DOI: 10.21611/qirt.2010.150
Google Scholar
[25]
Meola, C. et al. Application of infrared thermography and geophysical methods for defect detection in architectural structures. Engineering failure analysis v. 12, p.875–892, (2005).
DOI: 10.1016/j.engfailanal.2004.12.030
Google Scholar
[26]
Krankenhagen R., Kervalishvili G.N. and Maierh Ch. Influence of air gaps on the thermal behavior of plaster-concrete-bonds. 10th International Conference on Quantitative InfraRed Thermography July 27-30, 2010, Québec (Canada).
DOI: 10.21611/qirt.2010.067
Google Scholar