The Use of Infrared Thermography in the Analysis of Engineered Cementitious Composites

Article Preview

Abstract:

Non-destructive testing using infrared thermography has been used in civil construction basically in situations involving electrical conductors or mechanical wear that normally generate heat. In the specific case of materials, the application of thermography to metal stud is well documented, but there are few reports in the literature covering thermography in concrete; these are usually limited to the inspection of cracks and to the localization of water infiltration in prefabricated concrete structures. The present report evaluates the potential of the active infrared thermography method in the detection of changes in the macrostructure of engineering cementitious composite, as well as in order to estimate its thermal performance. The results show that thermography is able to detect changes in the macrostructure and is sensitive to temperature differences among the constituents of concrete.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 919-921)

Pages:

1868-1875

Citation:

Online since:

April 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Maldague X.P. Applications of infrared thermography. In: Nondestructive Evaluation, Terends in Optical Nondestrutive Testing (invited chapter), Pramod Rastogi Ed., pp.591-609, (2000).

DOI: 10.1016/b978-008043020-1/50040-5

Google Scholar

[2] Maldague X.P. Theory and practice of infrared technology for nondestructive testing, Wiley & Sons, Inc., New York, (2001).

Google Scholar

[3] Nondestructive Testing Handbook, Third Edition, Vol. 3 Infrared and Thermal Testing, Chap 15, ASNT, (2001).

Google Scholar

[4] Rogalski A. Infrared detectors: an overview. Journal of Alloys and Compounds 2004, 371: 53–57.

Google Scholar

[5] Meola C., Carlomagno G.M. Recent advances in the use of infrared Thermography. Institute of Physics Publishing Measurement Science and Technology 2004; 15: R27–R58.

DOI: 10.1088/0957-0233/15/9/r01

Google Scholar

[6] Castanedo C.I.N., Avdelidis P., Grenier M., Maldague X.P. and Bendada A. Active thermography signal processing techniques for defect detection and characterization on composite materials, Proc. SPIE 7661, 76610O (2010); doi: 10. 1117/12. 850733.

DOI: 10.1117/12.850733

Google Scholar

[7] Snell Jr J. R., Spring, R. W. Infrared Thermography Advances. Thermal NDT methods have continued to evolve with the advancements in thermal imaging and image processing. October 2, 2007. In NDT Magazine http: /www. ndtmag. com/Articles.

Google Scholar

[8] Wiggenhauser H. Active IR applications in civil engineering. Infrared Physics & Technology 2002, 43; p.233–238.

DOI: 10.1016/s1350-4495(02)00145-7

Google Scholar

[9] Meola C., Carlomagno G. M., Giorleo L. The use of infrared thermography for materials characterization. Journal of Materials Processing Technology 155–156 (2004) 1132–1137.

DOI: 10.1016/j.jmatprotec.2004.04.268

Google Scholar

[10] Barreira, E., Freitas, V. P. Evaluation of building materials using infrared thermography. Construction and building materials, v. 21, p.218–224, (2007).

DOI: 10.1016/j.conbuildmat.2005.06.049

Google Scholar

[11] Servais P, Gerlach N, Development of a NDT method using thermography for composite material inspection on aircraft using military thermal imager. V International Workshop, Advances in Signal Processing for Non Destructive Evaluation of Materials Québec City (Canada), 2-4 Aug. 2005, pp.197-202.

Google Scholar

[12] Shepard S.M. Flash Thermography of Aerospace Composites. IV Conference Pan-American the NDT. Buenos Aires – October (2007).

Google Scholar

[13] Maierhofer Ch., Brink A., Röllig M. and Wiggenhauser H. Transient thermography for structural investigation of concrete and composites in the near surface region Infrared Physics & Technology Volume 43, Issues 3-5, June 2002, Pages 271-278.

DOI: 10.1016/s1350-4495(02)00151-2

Google Scholar

[14] Sun, J.G. Deemer, C., Ellingson, W.A., Easler, T.E., Szweda, A., Craig, P.A. [Publication In 24. international thermal conductivity conference, Pittsburgh, PA (United States), 26-29 Oct 1997; Other Information: PBD: Sep (1997).

DOI: 10.2172/554854

Google Scholar

[15] Santulli C., Jeronimidis G, Measurement of surface void content on balsa wood using IRthermography, E-Journal of Non-Destructive Testing 11 n. 6, June (2006).

Google Scholar

[16] Lee, S., Lee, JH., Park, IK., Song, S., Choi MY. Thermographic damage detection of ceramic matrix composites during tension testing. Journal Key Engineering Materials 2006. Volumes 321 – 323: 825-830.

DOI: 10.4028/www.scientific.net/kem.321-323.825

Google Scholar

[17] Pan Y. P., Miller R.A., Chu T. P. and Filip P. Detection of defects. In commercial c/c composites using infrared thermography proceedings of the SEM Annual Conference June 1-4, 2009 Albuquerque New Mexico USA ©2009 Society for Experimental Mechanics Inc. Pp1-8.

Google Scholar

[18] Grinzato, E., Vavilov, V., Kauppinem, T. Quantitative infrared thermography in buildings. Energy and Buildings, v. 29 (1998) pp.1-9.

DOI: 10.1016/s0378-7788(97)00039-x

Google Scholar

[19] Balaras, C.A., Argiriou, A.A. Infrared thermography for building diagnostics. Energy and Buildings, v. 34 (2002) pp.171-183.

DOI: 10.1016/s0378-7788(01)00105-0

Google Scholar

[20] Avdelidis, N.P., Moropoulou, A. Emissivity considerations in building thermography. Energy and Buildings, v. 35 (2003) pp.663-667.

DOI: 10.1016/s0378-7788(02)00210-4

Google Scholar

[21] Clark MR, McCann DM, Forde MC. Application of infrared thermography to the non-destructive testing of concrete and masonry bridges. NDT & E International Independent Nondestructive Testing and Evaluation 2003; 36 (4): 265-275.

DOI: 10.1016/s0963-8695(02)00060-9

Google Scholar

[22] Ocaña, S.M., Guerreo, I.C., Requena, I.G. Evaluation of buildings materials using infrared thermography. Energy and Buildings, v. 36 (2004) pp.515-523.

Google Scholar

[23] Nahant M., Paez S., Leeuwen J. V. Detection by infrared thermography of the heat signature of diseases and defects in concrete structures of civil engineering. 10th International Conference on Quantitative InfraRed Thermography July 27-30, 2010, Québec (Canada).

DOI: 10.21611/qirt.2010.099

Google Scholar

[24] Grinzato E., Cadelano G., Bison P., Peron F. and Maldague X. High resolution and automatic survey of buildings by IR thermography 10th International Conference on Quantitative Infrared Thermography July 27-30, 2010, Québec (Canada).

DOI: 10.21611/qirt.2010.150

Google Scholar

[25] Meola, C. et al. Application of infrared thermography and geophysical methods for defect detection in architectural structures. Engineering failure analysis v. 12, p.875–892, (2005).

DOI: 10.1016/j.engfailanal.2004.12.030

Google Scholar

[26] Krankenhagen R., Kervalishvili G.N. and Maierh Ch. Influence of air gaps on the thermal behavior of plaster-concrete-bonds. 10th International Conference on Quantitative InfraRed Thermography July 27-30, 2010, Québec (Canada).

DOI: 10.21611/qirt.2010.067

Google Scholar