The Scheme Comparison of Integral Structure after Adding Steel Storey to Concrete Frame

Article Preview

Abstract:

Characteristics and applying conditions of lightweight steel structures in adding buildings are introduced, and the correlative calculating methods in designing are also discussed. The optimal layers in adding are proposed by using bottom storey shear as target parameters. The reactions of structure adding optimal layers are analyzed to judge the adding capacity of original structure. The economy comparison of different materials in adding is also discussed by the parameter of material cost. Using an adding project as an example, an appropriate adding scheme is chosen by this method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1506-1510

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] LvFengwei. STUDY ON THE DESIGN METHOD AND SEISMIC PERFORMANCE OF LIGHT STEEL ADDING STOREY STRUCTURE [D]. China: Southeast University, (2009).

Google Scholar

[2] CuiYanqiu, LiuFeng, Some problems in designing and applying of lightweight steel structure in added buildings, J. Journal of Shandong Institute of Architecture and Engineering , 2001(03): 30–33.

Google Scholar

[3] GB50023-2009. Standard for seismic appraisal of buildings, China Building Industry Press, BeiJing, (2009).

Google Scholar

[4] GB50011-2010. Code for seismic design of buildings, China Building Industry Press, BeiJing, (2010).

Google Scholar

[5] XieJingjing, MaLu, YangYong, Discussion on confirming method of the light steel adding storey structure damping ratio, J. Shanxi building, 2010(03): 83–85.

Google Scholar

[6] LiuYang, The discussion of damping ratio in mixed structure about storey-adding, J. Friend of Science Amateurs, 2011(09): 50–52.

Google Scholar

[7] LvFengwei, CaoShuangyin, ZongZongling, Solution to the Damping Ratio of the Building Added with Light-gauge Steel with Energy Method , J. Earthquake Resistant Engineering and Retrofitting, 2008(05): 100–102+106.

Google Scholar

[8] YangYofa, WangLifu, ON CALCULATION OF THE NON-PROPORTIONAL DAMPING EFFECT FOR THE INTERLAYER ISOLATION MASONRY BUILDING WITH FRAME STRUCTURE IN THE FIRST STOREY, J, Industrial Building, 2003(12): 47–48+76.

Google Scholar

[9] XueYantao, WeiChengji, SunR.F., Calculation Method for Damping Ration of Different Story Added Structures ( Strain Energy Method), J. Earthquake Resistant Engineering and Retrofitting, 2008(02): 91–95.

Google Scholar

[10] WangQi, GuZhengwei, The discuss of method of steel adding structure's damping ratio, J, Low temperature construction technology, 2012(11): 32–34.

Google Scholar

[11] HuYuxian, Earthquake Engineering (Second Edition), Seismological Press, BeiJing, (2006).

Google Scholar

[12] MaJianSuo, ZhangTao, etc., Analysis of seismic resistance of integral structure after adding steel storeys on top of concrete frame, J, Earthquake Engineering and Engineering Vibration, 2006(03): 118–120.

Google Scholar

[13] ZhangTao, WangYuanQing, ShiYongJiu, MaJiansuo, Analysis of Response Spectrum on the Seismic Properties of the Integral Structure after Adding Steel Storeys on Top of the Concrete Frame, J. Earthquake Resistant Engineering and Retrofitting, 2006(03): 95–100+105.

Google Scholar

[14] ZhangTao, WangYuanQing, ShiYongJiu, MaJiansuo, Analysis of time-history on the seismic properties of the integral structure after adding steel storeys on top of the concrete frame, J, Scientific research in Sichuan building, 2006(05): 140–143.

Google Scholar

[15] LiuYu, GaoXiaowang, ZhangTao, Analysis of Seismic Performance of the Storey-adding Structures of Light-weight Steel Based on SAP2000, J, Earthquake Resistant Engineering and Retrofitting, 2008(06): 100–104.

Google Scholar