Effect of New Corrosion Inhibitor on Electrochemical Behavior of Prestressed Steel Wire in Simulated Concrete Pore Solution

Article Preview

Abstract:

The polarization curve and AC impedance are used to study the impacts of new corrosion inhibitor on the prestressed steel wire electrochemistry action in the simulated concrete pore solution. The result shows that, the ammonium molybdate, DETA, propylene thiourea, 1,4-butynediol and other compound corrosion inhibitors are positive inhibitory corrosion inhibitors, with the components of passivator and healant of protective oxide film, which can contribute to the formation of a passive film of oxide on the rebar surface, repair the defects of rebar surface, coat the entire rebar with a passive film of oxide with good compactness and stability, prevent the chloride ion from penetration, reduce the free rate of iron ions, and thus achieve the anti-corrosion purpose.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 941-944)

Pages:

1390-1393

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Schupack M. A survey of the durability performance of post-tensioning tendons[J]. ACI Journal, 1978, 75(10): 501-510.

Google Scholar

[2] Schupack M, Suarez M G. Some recent corrosion embrittlement failures of prestressing system s in the United States[J] . PCI Journal, 1982, 27(2): 38-55.

DOI: 10.15554/pcij.03011982.38.55

Google Scholar

[3] Nurnberger U. Corrosion protection o f prestressing steels[R]. London: FIP State-of-the-Art Report, (1986).

Google Scholar

[4] Vehova r L, Kuhar V, Vehovar A. Hydrogen-assisted stress-corrosion of prestressing wires in a motoway viaduct [J]. Engineering Failure Analysis, 1998, 5(1): 21-27.

DOI: 10.1016/s1350-6307(97)00034-4

Google Scholar

[5] Valiente A. Stress corrosion failure o f large diameter pressure pipe lines of prestressed concrete[ J]. Engineering Failure Analysis, 2001, 8(3): 245-261.

DOI: 10.1016/s1350-6307(00)00010-8

Google Scholar

[6] Salas R M, Schokker A J, West J S, et al. Corrosion risk of bonded, post-tensioned concrete element [J] . PCI Journal, 2008, 53(1): 89-107.

DOI: 10.15554/pcij.01012008.89.108

Google Scholar

[7] Liu X M, Song G L, Lin H C, et al. A study survey of destruction caused by reinforcing steel in concrete [J]. Mater. Prot. 1996, 29(6):16-18.

Google Scholar

[8] Wang Ying, He Ping, Shi Yuanxiang, etc. The Action Mechanism of Corrosion Inhibitor to the Rebar in the Simulated Concrete Pore Solution and Motar [J], Journal of Nanjing University of Chemical Technology, 1998 , 20 (2) : 53 - 57.

Google Scholar