Study of Model Tests on Large-Span Tunnel’s Damage Caused by Overload with Arch Cover Method

Article Preview

Abstract:

In the process of large-span tunnel excavation by arch cover method, how to ensure the safety of construction and to reduce the influence on the surroundings and environment has arising wide attention of scholars both domestic and abroad. But now it is still in the stage of experience as to the rock pressure and its instability failure, especially to the research on rock overload damage. Regarding the large-span tunnel rock failure mechanism of progressive collapse by arch cover method, large-diameter modeling test are adopted to do systematical research on the rock failure phenomena as load increase. Determine its ultimate failure state by increasing vertical load, then we can get its failure characteristics and instability criterion in different rock support section.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 941-944)

Pages:

717-722

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Gaihong Kong and Fuping Li: Research on Environmental Protection and Control in Mining Sinking Region[J]. Hebei Coal. 2006, (1): 4-6. (In Chinese).

Google Scholar

[2] Guangquan Zhang, Zijian Du, Jinquan Song, et al: Monitoring and Analysis of Excavation-induced Subsidence of Subway Station Constructed by Arch Cover Method and Control Measures[J]. Chinese Journal of Rock Mechanics and Engineering. 2012, 31(z1): 3413-3420. (In Chinese).

Google Scholar

[3] Mengshu Wang: Shallow-buried Technology General Theory of Underground Plant Engineering[M]. Hefei: Anhui Education Press. 2004. (In Chinese).

Google Scholar

[4] Yingren Zheng and Shangyi Zhao: Limit State Finite Element Method for Geotechnical Engineering Analysis and Its Applications[J]. China Civil Engineering Journal, 2005, 38(1): 91-104. (In Chinese).

Google Scholar

[5] Guo Zhong: Arch-cover Method: A New Subsurface Excavation Construction For Metro Stations[J]. Urban Mass Transit. 2012, 15(8): 145-148. (In Chinese).

Google Scholar

[6] Haifeng Zhou and Qiang Fu: The Application of Arch Cover in Dalian Zhongshan Square Subway Station[J]. Shijie Jiayuan. 2012, (12): 55. (In Chinese).

Google Scholar

[7] Fangle Peng and Yanbo Cao: Finite Element Analysis Method on Bearing Capacity and Progressive Failure of Reinforced-sand Retaining Walls[J]. Chinese Journal of Rock Mechanics and Engineering. 2011, V30(S2): 3703-3713. (In Chinese).

Google Scholar

[8] Xuefeng Wu: Finite Element Simulation of Arch-cover Method in Soil-rock Compound Stratum. Urban Mass Transit. 2012, 15(8): 135-138. (In Chinese).

Google Scholar