Study on SO2, NO Removal from Flue Gas Using an Aqueous NaClO2 Solution with Oxidation Reduction Potential and pH Control
Abstract:
Removal of SO2 and NO from the flue gas using an aqueous sodium chlorite solution was achieved in a bubbling reactor, ORP and pH were used as monitoring parameter. The effect of pH, NaClO2 feeding rate and SO2 concentration on simultaneous removal of SO2 and NOx efficiencies were systematical investigated. The results showed that SO2 removal efficiency was always 100% and NOx removal efficiency could achieve 65% at optimized conditions, the optimized pH value of 5-5.5 was observed. The correlation analysis among ORP, original pH, NaClO2 feeding rate and input SO2 concentration was established using multiple regression equations.
Info:
Periodical:
Pages:
2221-2225
Citation:
Online since:
June 2014
Authors:
Keywords:
Price:
Сopyright:
© 2014 Trans Tech Publications Ltd. All Rights Reserved