Non-Pressure Heater Utilization on Low-Capacity Industrial Boiler

Article Preview

Abstract:

A new non-pressure waste heat recycling system was designed and arranged on KHSS0.5-0.7-AⅡ industrial coal-fired boiler to decrease the exhausted gas temperature about 35°C, improve the boiler efficiency about 3.2%. Results showed that this system can avoid low-temperature sulfur corrosion and operate in normal and intermittent water supply condition safely and economically.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 960-961)

Pages:

394-398

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Boqiang Lin: China's Energy Strategy Adjustment and the Energy Policy Optimize. [J] Electric Grid and Clear Energy, 2012(1): 1-3.

Google Scholar

[2] Ke Zhang, Dezu Yu: China's Industrial Boiler Status and Development. [J] Boiler and Pressure Vessel Safety in China, 2014(2): 17-21.

Google Scholar

[3] Fengrong Wang: A New Boiler Flue Gas Dew Point Temperature Calculation Method. [J] Boiler Technology, 1997(6): 19-20.

Google Scholar

[4] Hongkui Lian, Yan Li: Overview of Industrial Waste Heat Recycling Technology in China. [J] Energy conservation technology, 2011(3): 123-128.

Google Scholar

[5] Qunfeng Yang, Ying Cao: New Technology for Waste Heat Utilization of Low-capacity Industrial Boiler. [J] Energy Conservation Technology, 2012(4): 342-345.

Google Scholar