Abstract:

The test method of shallow plate load was used in the bearing capacity of foundation of Yushu City , doing two groups of loading test in different depths and doing survey and comparative test between test point nearby and sites in the same horizon.It gets the law of foundation soil bearing capacity value got by different test methods and provides the basis for Jilin Province to establish the local standards through the comparison of load test and geotechnical test , static cone penetration test and standard penetration test.