The Control Technology of the Z-Source Three-Phase Four-Leg Inverter Based on Computer Simulation

Article Preview

Abstract:

Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same leg conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth leg uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

688-694

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] F. Peng, X. Fang, B. Gu, et al. Trans. China Electrotech Soc, Vol. 19(2004), p.47.

Google Scholar

[2] M S. Shen, J. Wang , F Z. Peng , et al. . IEEE Industry Applications Society Annual Meeting, 2004: 142-1.

Google Scholar

[3] E. Wit and J. McClure, Statistics for Microarrays: Design, Analysis, and Inference, 5th Edition, John Wiley & Sons Ltd., Chichester, (2004).

DOI: 10.1080/07408170600844124

Google Scholar

[4] X. Ding, Q. Zhao,B. Cui,et al.Fuzzy PID controller for DC-link boost voltage in Z-source inverter.Proceedings of the CSEE,2008,28(24):31-38.

Google Scholar

[5] P. Chiang , Vilathgamuwa, D. M, Gajanayake,C. J, . Lim, T. Chen . Transient Modeling and Analysis of Pulse-Width Modulated Z-Source Inverter. EEEE Transaction on Power Electronics, 2009, 22(2): 498-507.

DOI: 10.1109/tpel.2006.889929

Google Scholar

[6] B. Li, G. Zhao, et al. Study on three-phase photovoltaic grid-connected inverter system based on compositive control. Power System Protection and Control, 2010, 38(21): 44-47.

Google Scholar

[7] L. Jun, C. Green, C. Feng. Increasing Voltage Utilization inSplit-Link, Four-Wire Inverters[J]. IEEE Trans. on Power Electronics. 2009, 6(24): 1562-1569.

DOI: 10.1109/tpel.2009.2013351

Google Scholar

[8] Loh P. C. VilathgamuwaD.M., Gajanayake C.J. WongL.T., Ang C. P. Z-Source Current—Type Inverters: Digital Modulation and Logic Implementation. IEEE Transactions on Power Electronics, 2007 22(1): 169-177.

DOI: 10.1109/tpel.2006.886618

Google Scholar