The Effect of Evaporator Pressure Behavior at Start-Up Conditions of Air Conditioning Systems to Energy Consumption and Heat Transfer

Article Preview

Abstract:

The energy issue is necessary today due to the decrease in fossil energy and its impacts on the environment. It is important to use energy effectively. In the air conditioning sector, the energy consumption of air conditioners is the top energy user in buildings. The air conditioner user needs to find the best way to operate the air conditioner. In the present research, the effect of pressure behavior at start-up conditions on the energy consumption and heat transfer process is analyzed. The result shows that the pressure behavior affects the evaporator temperature, specific heat, and thermal conductivity in liquid and vapor conditions. In the first 20-second AC operation, the energy consumption of the AC compressor increases significantly before the compressor work slowly decreases at 40-second operation and remains constant at steady conditions. The negligible heat transfer at the first 20-second AC operation increases steeply for 40 seconds. The heat transfer is steady at 60 seconds of operation and above.

You might also be interested in these eBooks

Info:

Periodical:

Engineering Headway (Volume 18)

Pages:

3-12

Citation:

Online since:

February 2025

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2025 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Maria Rosita and Rizki Caturini, Udara panas, penjualan AC semakin deras, (accessed on 11th July 2022, https://industri.kontan.co.id/news/udara-panas-penjualan-ac-semakin-deras-1 )

Google Scholar

[2] Sanken, 2016, Sehatkah AC di rumah anda, (accessed on 8th July 2022, https://www.sanken.co.id/47/promo-terkini/sehatkah-ac-di-rumah-anda.html Sanken Electronic Indonesia)

Google Scholar

[3] Suwondo, A. P. (2020). Pengaruh Kecepatan Putar Kipas Evaporator Ruang terhadap Karakteristik Water Chiller Menggunakan Panjang Pipa Kapiler 130 cm. Skripsi, Universitas Sanata Dharma, Yogyakarta

Google Scholar

[4] Uap, D. S. K., & Setiawan, E. D (2019). Pengaruh Putaran Kipas Outlet Terhadap Karakteristik Mesin Penghasil Aquades. Skripsi, Universitas Sanata Dharma, Yogyakarta.

Google Scholar

[5] Simamora, N (2018). Pengaruh kecepatan aliran udara terhadap karakteristik mesin penghasil air dari udara. Skripsi, Universitas Sanata Dharma, Yogyakarta.

DOI: 10.33508/wt.v20i2.3521

Google Scholar

[6] Hajidavalloo, E., & Eghtedari, H. (2010). Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser. International journal of refrigeration, 33(5), 982-988.

DOI: 10.1016/j.ijrefrig.2010.02.001

Google Scholar

[7] Kosasih, E. A., Zikri, A., & Dzaky, M. I. (2022). Water vapor desorption from silica gel in a combined drying and double-condenser compression refrigeration system. Heliyon, e09757.

DOI: 10.1016/j.heliyon.2022.e09757

Google Scholar

[8] Xu, Z. Y., & Wang, R. Z. (2018). Comparison of absorption refrigeration cycles for efficient air-cooled solar cooling. Solar Energy, 172, 14-23.

DOI: 10.1016/j.solener.2018.04.004

Google Scholar

[9] Siang, J. T., & Sharifian, A. (2018, August). Effect of inlet pressure, size and wind speed of an evaporator on amount of refrigerant charge and performance of a portable propane air conditioner. In 2018 4th International Conference on Science and Technology (ICST) (pp.1-6). IEEE.

DOI: 10.1109/icstc.2018.8528623

Google Scholar

[10] Ji, W., Cai, J., Ji, J., & Huang, W. (2020). Experimental study of a direct expansion solar-assisted heat pump (DX-SAHP) with finned-tube evaporator and comparison with conventional DX-SAHP. Energy and Buildings, 207, 109632.

DOI: 10.1016/j.enbuild.2019.109632

Google Scholar

[11] Kim, M. H., & Bullard, C. W. (2001). Dynamic characteristics of a R-410A split air-conditioning system. International Journal of Refrigeration, 24(7), 652-659.

DOI: 10.1016/s0140-7007(00)00088-8

Google Scholar

[12] Yun, Y., & Chang, Y. S. (2021). Refrigerant charge prediction of vapor compression air conditioner based on start-up characteristics. Applied Sciences, 11(4), 1780.

DOI: 10.3390/app11041780

Google Scholar

[13] Siang, JT, Sharifian, A. (2017) Performance of a single-duct portable propane air conditioning system under different refrigerant charge levels. Heat Transfer–Asian Research. 46: 1246-1261.

DOI: 10.1002/htj.21271

Google Scholar

[14] Rahadian, E.Y., Hidajat, A., Subekti, B., Parhea, A.S., Anisa, N., & Fauziani, R. Kajian Kenyamanan Termal Ruang Kuliah Kasus Gedung 18 Kampus Itenas Bandung. In Seminar Nasional ITENAS. Jurusan Arsitektur.

Google Scholar

[15] Ji, Weian, et al. (2020). Experimental study of a direct expansion solar-assisted heat pump (DX-SAHP) with finned-tube evaporator and comparison with conventional DX-SAHP." Energy and Buildings 207 (2020): 109632.

DOI: 10.1016/j.enbuild.2019.109632

Google Scholar