Practical Use of Half-Cell Potential Method for NDE of Corrosion of Reinforced Concrete Structure

Abstract:

Article Preview

Info:

Periodical:

Key Engineering Materials (Volumes 270-273)

Edited by:

Seung-Seok Lee, Dong-Jin Yoon, Joon-Hyun Lee and Sekyung Lee

Pages:

1638-1644

Citation:

J. W. Kyung et al., "Practical Use of Half-Cell Potential Method for NDE of Corrosion of Reinforced Concrete Structure ", Key Engineering Materials, Vols. 270-273, pp. 1638-1644, 2004

Online since:

August 2004

Export:

Price:

$38.00

[1] P.H. Emmons and A.M. Vaysburd: Corrosion protection in concrete repair: myth and reality, Concrete International, Vol. 19 (1997), pp.47-56.

[2] T. Ohshiro, S. Tanikawa and N. Goto: A study on corrosion evaluation of steel reinforcements in concrete, Proc. of JCI, Vol. 13, No. 1 (1991), pp.503-508.

[3] ASTM C876: Standards test method for half-cell potentials of reinforcing steel in concrete, (1991).

[4] S. Misra and T. Uomoto: Corrosion of rebars under different corrosions, Proc. of JCI, Vol. 12, No. 2 (1990), pp.825-830.

[5] H. Tamura, M. Nagayama and K. Shimozawa: A case study on reinforcement corrosion in an existing RC structure, Proc. of JCI, Vol. 14, No. 1 (1992), pp.763-768.

[6] M. Otomaru, Y. Murakami and M. Ohtsu: Half-cell potentials analysis by BEM for corrosion monitoring, Proc. of JCI, Vol. 12, No. 1 (1990), pp.539-544.

[7] M. Ohtsu and J.W. Kyung: Improvement of half-cell potential measurement for nondestructive evaluation of rebar corrosion, Proc. of JSCE, Vol. 86, No. 2 (2001), pp.828-829.

[8] C.A. Brebbia: The boundary element method for engineers, Pentech Press Ltd., London, (1978).

[9] M. Yokota: Study on corrosion monitoring of reinforcing steel bars in 36-year-old actual concrete structures, Proc. of JSCE, Vol. 20, No. 1 (1998), pp.155-164.