Analysis on Load-Deformation Curves of the Concentrically Compressed Concrete Filled Circular CFRP-Steel Tubular Stub Columns

Article Preview

Abstract:

Based on experimental study and stress-strain curve of the concrete confined by circular CFRP-steel tube subjected to axial load, the fiber element approach was used to analyse load-deformation curves of the concentrically compressed concrete filled circular CFRP-steel tubular stub columns, and it shows that the results predicted check well with those of the tests and are on the safe side. Influences of confinement factor of the steel tube and the that of the CFRP tube on curves were analysed. The typical load-deformation curves were proposed and it could be defined as following four stages, e.g., elasticity stage, nonlinear stage, strengthening stage and softening stage. The method presented here is suitable for load-deformation curves analysis of the concentrically compressed concrete filled steel tubular (CFST) stub columns with circular cross-section also.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 400-402)

Pages:

507-512

Citation:

Online since:

October 2008

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2009 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Han L H: Concrete Filled Steel Tubular Structures-Theory and Practice (China Science Press, Beijing 2004). (in Chinese).

Google Scholar

[2] Fardis M N and Khalili H H, FRP-Encased Concrete as A Structural Material, Magazine of Concrete Research, Vol. 34, No. 121, 1982, pp.191-202.

DOI: 10.1680/macr.1982.34.121.191

Google Scholar

[3] Wang Q L, Zhao Y H and Gu W, A Presumption on the Concrete Filled Circular CFRP-Steel Composite Tube Structures, Journal of Shenyang Architecture and Civil Engineering Institute, Vol. 19, No. 4, 2003, pp.272-274. (in Chinese).

Google Scholar

[4] Xiao Y, He W H and Choi K K, Confined Concrete-Filled Tubular Columns, Journal of Structural Engineering, ASCE, Vol. 131, No. 3, 2005, pp.488-497.

DOI: 10.1061/(asce)0733-9445(2005)131:3(488)

Google Scholar

[5] Tao Z and Yu Q: �ew Kinds of Composite Structural Columns-Experiment, Method and Theory (China Science Press, Beijing 2006). (in Chinese).

Google Scholar

[6] Tao Z, Han L H and Zhuang J P, Axial Loading Behavior of CFRP Strengthened Concrete-Filled Steel Tubular Stub Columns, Advances in Structural Engineering, Vol. 10, No. 1, 2007, pp.37-46.

DOI: 10.1260/136943307780150814

Google Scholar

[7] Wang Q L, Gu W and Zhao Y H, Experimental Study on Concentrically Compressed Concrete Filled Circular CFRP-Steel Composite Tubular Stub Columns,. Journal of China Civil Engineering, Vol. 38, No. 10, 2005, pp.44-48. (in Chinese).

DOI: 10.1016/b978-008044637-0/50098-6

Google Scholar

[8] Zhao Y H, Gu W and Wang Q L, Experimental Study on Concentrically Compressed Concrete Filled Hollow CFRP-Steel Stub Columns with Circular Cross-Section, in: Proceeding of the 2nd International Conference on Steel and Composite Structures, edited by Choi C K, Lee H W and Kwak H G, Seoul, Korea, 2004, pp.712-721.

DOI: 10.1016/b978-008044637-0/50098-6

Google Scholar

[9] Wang Q L, Wang J Y, Zhang Y D, et al, Mechancal Property Analysis about the Concentrically Compressed Concrete Filled Circular CFRP-Steel Tubular Stub Columns, Journal of Shenyang Jianzhu University, Vol. 21, No. 3, 2005, pp.185-188. (in Chinese).

DOI: 10.1016/b978-008044637-0/50099-8

Google Scholar

[10] Wang Q L, Zhao C L, Zhang H B, et al, Simplified Strength Calculation of the Concentrically Compressed Concrete Filled CFRP-Steel Tubular Stub Columns, Journal of Shenyang Jianzhu University, Vol. 21, No. 6, 2005, pp.612-615. (in Chinese).

DOI: 10.1016/b978-008044637-0/50099-8

Google Scholar

[11] Wang Q L, Zhu H F and Gao Y F, Constitutive Relationship of Concrete Confined by Circular CFRP-Steel Composite Tube under Concentrical Load, Journal of Shenyang Jianzhu University, Vol. 23, No. 2, 2007, pp.199-203. (in Chinese).

Google Scholar

[12] Han L H, Yao G H and Zhao X L, Tests and Calculations of Hollow Structural Steel (HSS) Stub Columns Filled with Self-Consolidating Concrete (SCC), Journal of Constructional Steel Research, Vol. 61, No. 9, 2005, pp.1241-1269.

DOI: 10.1016/j.jcsr.2005.01.004

Google Scholar