Abstract:

The screening of urine human serum albumin (HSA) is significant for the early diagnosis and intervention of the nephropathia. This study developed sensitive HSA detection assay with a self-made portable-SPR biosensor based on the reflection light intensity interrogation. Anti-HSA monoclonal antibody was immobilized onto the gold sensing area and a directive assay for HSA was developed. A detection range of 1–100μg/mL HSA was found. The described label-free, real-time immunoassay for the quantification of HSA in urine is a rapid, sensitive, alternative method available for the clinic detection.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 562-565)

Pages:

408-411

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Viberti GC, Hill RD and Jarrett RJ et al., Microalbuminuria as a predictor of clinical nephropathy in insulin-dependent diabetes mellitus. Lancet I (1982)1430-1432.

DOI: 10.1016/s0140-6736(82)92450-3

Google Scholar

[2] Giampietro O, Clerico A and Cruschelli L et al., Measurement of urinary albumin excretion rate (AER) in normal and diabetic subjects: comparison of two recent radioimmunoassays. J Nucl Med Allied Sci 31 (1987)321-326.

Google Scholar

[3] M Marre, JP Claudel and P Ciret et al., Laser immunonephelo metry for routine quantification of urinary albumin excretion. Clinical Chemistry .33(1987)209-213.

DOI: 10.1093/clinchem/33.2.209

Google Scholar

[4] Jacoline.W.Brinkman,Stephan.J.Bakker,and Ron et al., Mechanism and Measurement of Albuminuria. Kidney International 66(2004)S69–S75.

Google Scholar

[5] Iva Navra´tilova´ , Petr Skla´dal , Vladimı´r Viklicky´. Development of piezoelectric immunosensors formeasurement of albuminuria. Talanta .55(2001):831-839.

Google Scholar

[6] IVA NAVRA´TILOVA ´ and PETR SKLA´ DAL, Immunosensor for the Measurement of Human Serum Albumin in Urine Based on the Spreeta Surface Plasmon Resonance Sensor .Supramolecular Chemistry.15 (2003), 109-115

DOI: 10.1080/1061027031000090352

Google Scholar

[7] H Cai, H Li, L Zhang, X Chen,Dafu Cui Portable surface plasmon resonance instrument based on a monolithic scanner chip Biomedical Engineering and Informatics (BMEI), 2010 3rd International Conference.4(2010)1553-1555

DOI: 10.1109/bmei.2010.5639370

Google Scholar

[8] Bo Johnsson, Stefan Löfås and Gabrielle Lindqust. Immobilization of proteins to a carboxymethyldextran-modified gold surface for biospecific interaction analysis in surface plasmon resonance sensors.Anal.Biochem. 198(1991)268-277.

DOI: 10.1016/0003-2697(91)90424-r

Google Scholar