Sensor Fusion on Structural Monitoring Data Analysis: Application to a Cable-Stayed Bridge

Article Preview

Abstract:

This paper illustrates an application of Bayesian logic to monitoring data analysis and structural condition state inference. The case study is a 260 m long cable-stayed bridge spanning the Adige River 10 km north of the town of Trento, Italy. This is a statically indeterminate structure, having a composite steel-concrete deck, supported by 12 stay cables. Structural redundancy, possible relaxation losses and an as-built condition differing from design, suggest that long-term load redistribution between cables can be expected. To monitor load redistribution, the owner decided to install a monitoring system which combines built-on-site elasto-magnetic and fiber-optic sensors. In this note, we discuss a rational way to improve the accuracy of the load estimate from the EM sensors taking advantage of the FOS information. More specifically, we use a multi-sensor Bayesian data fusion approach which combines the information from the two sensing systems with the prior knowledge, including design information and the outcomes of laboratory calibration. Using the data acquired to date, we demonstrate that combining the two measurements allows a more accurate estimate of the cable load, to better than 50 kN.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 569-570)

Pages:

812-819

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] D. Zonta, P. Esposito, M. Pozzi, M. Molignoni, R. Zandonini, M. Wang, D. Inaudi, D. Posenato and B. Glisic, Monitoring Load Redistribution in a Cable-Stayed Bridge, Proc. of the 5th European Conference on Structural Control, Genova, (2012).

DOI: 10.1117/12.917540

Google Scholar

[2] Information on http: /www. roctest-group. com.

Google Scholar

[3] D. Zonta, P. Esposito, M. Molignoni, R. Zandonini, M. Wang, Y. Zhao, J. Yim and B. T. Gorriz, Calibration of elasto-magnetic sensors for bridge-stay cable monitoring, Proc. of the Sixth European Workshop on Structural Health Monitoring 2012, Dresden, (2012).

Google Scholar

[4] Information on http: /www. iis-system. it.

Google Scholar

[5] P. Esposito, Structural Monitoring of the North Trento-Rocchetta Adige bridge, Master thesis, Trento, (2010).

Google Scholar

[6] H.B. Mitchell, Data Fusion: Concepts and Ideas, Springer, Berlin-Heidelberg, (2012).

Google Scholar

[7] R.M. Measures, Structural monitoring with fiber optic technology, Academic Press, London, (2001).

Google Scholar

[8] B. Glisic, D. Inaudi, Fiber optic methods for Structural Health Monitoring, John Wiley & Sons, Chichester, (2007).

DOI: 10.1002/stc.353

Google Scholar

[9] A. Jarosevic, Magnetoelastic Method Of Stress Measurement In Steel, Proc. of the NATO Advanced Research Workshop, Warsaw, (1998).

Google Scholar

[10] S. Sumitro, M. Kurokawa and M.L. Wang, Elasto-magnetic sensor utilization on steel cable stress measurement, Proc. of the first fib congress, Concrete Structures in the 21th Century, Osaka, (2002).

Google Scholar

[11] P.C. Gregory, Bayesian Logical Data Analysis for the Physical Sciences: a comparative approach with Mathematica support, Cambridge University Press, Cambridge, (2005).

DOI: 10.1017/cbo9780511791277

Google Scholar

[12] D.S. Sivia, Data Analysis: a Bayesian Tutorial, Oxford University Press, Oxford, (1996).

Google Scholar

[13] W.M. Bolstad, Understanding Computational Bayesian Statistics, John Wiley & Sons, California, (2010).

Google Scholar

[14] W.K. Hastings, Monte Carlo sampling methods using Markov chains and their applications, Biometrika. 57 (1970), 97-109.

DOI: 10.1093/biomet/57.1.97

Google Scholar