Ultrasonic Corrosion Fatigue Behaviorof Duplex Stainless Steel
Abstract:
Ultrasonic Corrosion Fatigue Tests were Conducted for SUS329J3L in Air and 3%NaCl Aqueous Solution. Reduction of Giga-Cycle Corrosion Fatigue Strength was 12.5%. Corrosion Pit was Observed on Corrosion Fatigue Crack Initiation Area. Striation was Predominantly Observed on Crack Propagation Area both in Air and 3% Nacl Aqueous Solution. it can be Concluded that the Reduction of Corrosion Fatigue Strength of SUS329J3L is due to the Corrosion Pit Formation at Corrosion Fatigue Crack Initiation Area.