Cyclic Behavior of Panel Zone in Steel Moment Frame under Bidirectional Loading

Article Preview

Abstract:

This paper aims to examine the cyclic behavior of panels in steel moment frame subjected to bidirectional and unidirectional loading and to demonstrate the differences of panel behavior under two loading modes. The specimens were composed of wide-flange beams and square tube columns, and the panel zones were designed to yield before columns and beams. Experimental results showed that specimens subjected to bidirectional loading suffered severe damage, caused by the weld fracture at the corner of panel-to-diaphragm weld, and failed at 0.06 rad and 0.04 rad story drift for specimens with panel aspect ratio of 1.4 and 2.0, respectively. Specimens subjected to unidirectional loading developed a story drift of 0.06 rad without strength reduction. The panels contributed about 60%-80% story drift and dissipated approximately 80% of total input energy. Panels with higher aspect ratio showed smaller plastic shear strength because of the effect of flexural yielding in panels. Moreover, the beams were found to present plastic moments 20%-50% lower than theoretical values, which was attributed to the small panel-to-beam strength ratio.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

361-368

Citation:

Online since:

February 2018

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2018 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. Krawinkler, V.V. Bertero, E.P. Popov, Shear behavior of steel frame joints, J. Struct. Div. 101(11) (1975) 2317–2336.

DOI: 10.1061/jsdeag.0004206

Google Scholar

[2] K.D. Kim, M.D. Engelhardt, Monotonic and cyclic loading models for panel zones in steel moment frames, J. Constr. Steel Res. 58(5) (2002) 605-635.

DOI: 10.1016/s0143-974x(01)00079-7

Google Scholar

[3] G. Brandonisio, A. De Luca, E. Mele, Shear strength of panel zone in beam-to-column connections, J. Constr. Steel Res. 71 (2012) 129-142.

DOI: 10.1016/j.jcsr.2011.11.004

Google Scholar

[4] S. Kuwahara, K. Inoue, The shear force loading test for the beam-to-column joint panels of rectangular and circular hollow section, J. Struct. Constr. Eng. 62(502) (1997) 149-156 [in Japanese].

DOI: 10.3130/aijs.62.149_2

Google Scholar

[5] H. Namba, M. Tabuchi, T. Tanaka, S. Kitaoka, Behaviour on tapered joint panels in RHS column to beam connections, J. Struct. Constr. Eng. 69(579) (2004) 95-102 [in Japanese].

DOI: 10.3130/aijs.69.95_2

Google Scholar

[6] H. Namba, M. Tabuchi, T. Tanaka, Evaluation for full plastic strength of joint panels in hollow section column to beam connections, Steel Constr. Eng. 11(42) (2004) 15-28 [in Japanese].

Google Scholar

[7] AIJ, Recommendation for design of connections in steel structures, Architectural Institute of Japan, Tokyo, 2012 [in Japanese].

Google Scholar