Methodology for Determination of the Requirement of Repair of External Facades of ETICS due to the Occurrence of Microorganisms

Article Preview

Abstract:

The submitted article deals with a relatively new phenomenon, which is monitoring and solution to minimization of microorganisms ́ occurrence on the surface of the External Thermal Insulation Composite Systems (ETICS). The importance of the solution has been becoming more important both from the point of view of health risk for inhabitants and accelerated degradation of particular layers of the ETICS due to the presence of these microorganisms. The article submits conceptual methodological solution to the reduction of count of microorganisms on the ETICS surface from diagnosis, setting out criteria for the necessity of determination of macrobiotic biodeteriogens to subsequent rehabilitation design.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

153-159

Citation:

Online since:

August 2018

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2018 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Sulakatko, V., Lill, I., & Witt, E. Methodological framework to assess the significance of External Thermal Insulation Composite System (ETICS) on-site activities. Energy Procedia, 96, (2016), 446-454.

DOI: 10.1016/j.egypro.2016.09.176

Google Scholar

[2] Warscheid, T., Braams, J. Biodeterioration of stone. International Biodeterioration & Biodegradation, 46 (2000) 343–368.

DOI: 10.1016/s0964-8305(00)00109-8

Google Scholar

[3] Wasserbauer, R. Biological Degradation of Buildings (In Czech), first ed. Praha: ABF, Prague, (2000).

Google Scholar

[4] Ximenes, S., De Brito, J., Gaspar, P. L., Silva, A. Modeling the degradation and service life of ETICS in external walls. Materials and Structures, 48(7), (2015), 2235-2249.

DOI: 10.1617/s11527-014-0305-8

Google Scholar

[5] Silva, A., de Brito, J., Gaspar, P. L. Application of the factor method to maintenance decision support for stone cladding. Automation in Construction, 22, (2012), 165-174.

DOI: 10.1016/j.autcon.2011.06.014

Google Scholar

[6] European Technical Approval Guideline ETAG 004:2013 External Thermal Insulation Composite Systems with Rendering.

Google Scholar

[7] ČSN 73 2578 –Test for water-tightness of surface finish of building structures.

Google Scholar

[8] Ryparová, P.; Rácová, Z. Characterization of Microorganism from Individual Layers of the Building Envelope (ETICS) and Methods of Their Sampling. In Trans Tech Publications (CRRB 2015), Prague 2015. pp.196-200.

DOI: 10.4028/www.scientific.net/kem.714.196

Google Scholar

[9] ČSN EN ISO 4833-1 Microbiology of the food chain – Horizontal method for the enumeration of microorganisms.

Google Scholar