The Comparison of Polyethersulfone (PES)/N-Methyl 2-Pyrrolidone (NMP) on the Fabrication of Hollow Fiber Membranes with Commercial Membranes for Applications Hemodialysis

Article Preview

Abstract:

The decrease in kidney function is caused by an increase in creatinine and urea levels in the blood; this is the cause of chronic kidney failure (GGK) in patients. Hemodialysis membrane technology is an alternative treatment for chronic renal failure by separating dissolved components in the blood, such as creatinine and urea, using dialysate fluid by passing through the membrane pores. Therefore, the characteristics of hemodialysis membranes become essential to meet the requirements of a dialyzer. This study aimed to compare the features of the resulting hemodialysis membrane with several commercial membranes. In this study, there were four kinds of commercial membranes used, namely F8HPS, FX80, LO PS 15, and Nipro Elisio 15-H, were compared with membrane products that have variations in the composition of polyethylene (PES) using N-methyl-2-pyrolidone (NMP) solvents are 22.5; 24; and 25%. The membrane manufacturing method uses nonsolvent-induced precipitation (NISP). The resulting hollow fiber membrane is characterized by surface morphology using a scanning electron microscope (SEM), functional groups (FT-IR), and tensile test analysis (DMA). The results showed that the composition of PES/NMP is 25%, close to the characteristics of Nipro Elisio 15-H.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volume 1114)

Pages:

43-50

Citation:

Online since:

February 2024

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2024 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Riskesdas, "Hasil Utama Riset Kesehatan Dasar," 2018.

Google Scholar

[2] M. Mulder, "Mulder, M. - 1996 - Basic Principles of Membrane Technology, 2E.pdf." p.576, 1996.

Google Scholar

[3] H. Waheed, F. T. Minhas, and A. Hussain, "Cellulose acetate/sericin blend membranes for use in dialysis," Polym. Bull., vol. 75, no. 9, pp.3935-3950,2018.

DOI: 10.1007/s00289-017-2238-1

Google Scholar

[4] N. P. Singh, R. Bansal, A. Thakur, R. Kohli, R. C. Bansal, and S. K. Agarwal, "Effect of membrane composition on cytokine production and clinical symptoms during hemodialysis: A crossover study," Ren. Fail., vol. 25, no. 3, p.419–430, 2003.

DOI: 10.1081/JDI-120021154

Google Scholar

[5] S. K. Bowry, E. Gatti, and J. Vienken, "Contribution of polysulfone membranes to the success of convective dialysis therapies," Contrib. Nephrol., vol. 173, p.110–118, 2011.

DOI: 10.1159/000328960

Google Scholar

[6] D. Zhong, Z. Wang, J. Zhou, and Y. Wang, "Additive-free preparation of hemodialysis membranes from block copolymers of polysulfone and polyethylene glycol," J. Memb. Sci., vol. 618, no. September 2020, p.118690, 2021.

DOI: 10.1016/j.memsci.2020.118690

Google Scholar

[7] K. Li et al., "Effect of polyethylene glycol molecular weight and concentration on the performance of polyethersulfone hollow fiber ultrafiltration membranes," Gongneng Cailiao/Journal Funct. Mater., vol. 45, no. 4, p.04121–04124, 2014.

Google Scholar

[8] M. Irfan et al., "Fabrication and performance evaluation of blood compatible hemodialysis membrane using carboxylic multiwall carbon nanotubes and low molecular weight polyvinylpyrrolidone based nanocomposites," J. Biomed. Mater. Res. - Part A, vol. 107, no. 3, p.513–525, 2019.

DOI: 10.1002/jbm.a.36566

Google Scholar

[9] Yegani, "Study on the Impact of Polymer Concentration and Coagulation Bath Temperature on the Porosity of Polyethylene Membranes Fabricated Via TIPS Method," J. Membr. Sep. Technol., no. 0098, p.100–107, 2012.

DOI: 10.6000/1929-6037.2012.01.02.4

Google Scholar

[10] G. R. Guillen, Y. Pan, M. Li, and E. M. V. Hoek, "Preparation and characterization of membranes formed by nonsolvent induced phase separation: A review," Ind. Eng. Chem. Res., vol. 50, no. 7, p.3798–3817, 2011.

DOI: 10.1021/ie101928r

Google Scholar

[11] M. Cheryan, Ultrafiltration and Microfiltration Handbook. Pennsylvania: Technomic Publishing Company, Inc., 1998.

Google Scholar

[12] S. K. Yamashita A.C., Dialysis Membranes-physicochemical structures and features, 1st Ed. Rijeka: Intech, 2015.

Google Scholar

[13] N. Said et al., "The effect of air gap on the morphological properties of PSf/PVP90 membrane for hemodialysis application," Chem. Eng. Trans., vol. 56, p.1591–1596, 2017.

Google Scholar

[14] M. Khayet, "The effects of air gap length on the internal and external morphology of hollow fiber membranes," Chem. Eng. Sci., vol. 58, no. 14, p.3091–3104, 2003.

DOI: 10.1016/S0009-2509(03)00186-6

Google Scholar

[15] A. Mushtaq, H. Bin Mukhtar, and A. M. Shariff, "FTIR study of enhanced polymeric blend membrane with amines," Res. J. Appl. Sci. Eng. Technol., vol. 7, no. 9, p.1811–1820, 2014.

DOI: 10.19026/rjaset.7.466

Google Scholar