Measurement of Discharged Energy and Pressure of Underwater Shockwave Changing Materials of Contact Switch in High Voltage Power Supply

Article Preview

Abstract:

We have developed the high voltage power-supply unit for ingenerate high pressure due to underwater shockwave by discharging and electrical sparking consists of Cockcroft-Walton circuit. This power supply has the problem of the contact switch operation due to melting of materials of contact switch by electrical spark. We have studied the optimization of materials of contact switch by reducing energy loss and problem of operation. In this research, We changed material of contact switch metal to carbon. And verified that new contact switch made of carbon is effective to reduce energy loss and solve problem of contactor switch operation.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

250-255

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] R. Matsubara, T. Matsui, O. Higa, K. Higa, S. Itoh, draft of JSAP lecture Vol. 72 2a-ZJ-9, (2011).

Google Scholar

[2] R. Matsubara, T. Matsui, O. Higa, K. Higa, S. Itoh, draft of JSAP-Kyushu chapter lecture, 37 (2011) 26Fa-12.

Google Scholar

[3] R. Matsubara, T. Matsui, O. Higa, K. Higa, S. Itoh, draft of ASME PVP2012-78821, (2012).