Effects of Sodium Nitrite, Sodium Dichromate and Benzoic Acid as Inhibitors in the Protection of Mild Steel in Water

Article Preview

Abstract:

In Petrobrás SA refineries, there are thousands of heat exchangers in which cooling water is treated for recycling, often by outsourced companies. In all of these refineries there happens shutdown for corrective maintenance of the exchangers by problems related to corrosion caused by the cooling water, requiring about four days to repair a unit. The shutdown of a production line results in loss of revenue between U$ 200,000.00 and U$ 300,000.00 per day. To control the cooling water quality, it is used coupons for corrosion analysis. Tests are limited to visual inspection and by mass loss analysis. In this work, inhibitors such as sodium nitrite, sodium dichromate and benzoic acid are used to protect metals immersed in water in order to avoid the corrosion and consequently the shutdown of the exchanger for corrective maintenance.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

433-439

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] V. Gentil: Corrosão. (3ª ed. LTC Rio de Janeiro, 1996).

Google Scholar

[2] S.J. Findlay, N.D. Harrison: Why aircraft fail. Materialstoday, Kidlington (2002), p.18.

Google Scholar

[3] P.R.L. Helene: Corrosão em armaduras para concreto armado. São Paulo: Pini. ALMEIDA, Maria das Vitórias Vieira. Contribuição ao estudo da corrosão no concreto armado através de medidas de polarização potenciostática. 80p. Dissertação (Mestrado em Engenharia Mecânica) - Centro de Tecnologia, UFRN, (1996).

DOI: 10.4322/cbpat.2022.056

Google Scholar

[4] E.N. Codaro, R.Z. Nakazato, A.L. Horovistiz, L.M.F. Ribeiro, R.B. Ribeiro and L.R.O. Hein: Materials Science and Engineering A Vol. 341 (2003), p.202.

DOI: 10.1016/s0921-5093(02)00218-6

Google Scholar

[5] A.M.; Rosenberg, J.M. Gaidis: Materials Performance (1979), p.45.

Google Scholar

[6] T. Moon, D. Horsup: Nace International Corrosion (2002), Paper 02298.

Google Scholar

[7] A. Denzine, M. Reading: An Improved, Rapid Corrosion Rate Measurement Technique for All Process Environments. Materials Performance January 1998 35.

Google Scholar

[8] U. Nürberger, W. Beul, Corrosion of Stainless steel Reinforcement in Cracked concrete; in Cost 521, "Corrosion of Steel in Reinforced Structures. Final Report, Edited by R. Wydert, Luxemburg, (2002).

Google Scholar

[9] L. Bertolini, M. Gastaldi, T. Pastore, M.P. Pedeferri, P. Pedeferri, Effects of Galvanic Coupling between Carbon Steel and Stainless Steel Reinforcement in Concrete", Int. Conf. on "Corrosion and Rehabilitation of Reinforced Concrete Structures, Federal Highway Administration, Orlando, (1998).

DOI: 10.1533/9781845692285.62

Google Scholar

[10] D.B. McDonald, M.R. Sherman, D.W. Pfeifer, and Y.P. Virmani, Stainless Steel Reinforcing as Corrosion Protection, Nickel Development Institute, Reprint Series 14034, August (1995).

Google Scholar