Investigation of the Relationship of Muscle Mechanical Characteristics with Biosignal Energy

Article Preview

Abstract:

Based on biosignal energy equality to the work performed by a muscle, in the estimation of energy dissipation within a biolotronic system, analytical expressions have been derived that have helped to calculate major mechanical characteristics of the muscle including elongation of the muscle, speed and acceleration of such elongation. The paper presents the analysis of relevant digital methods alongside with the formulae for the calculation of major mechanical characteristics when the relationship of a muscle biosignal that is presented in a graphical way. As shown, fatigue of the muscle is characterized by one of extreme points of the phase shift function. The values of the first and the second derivatives of the elongation function may be used for the evaluation of functional capacity of the muscle.

You might also be interested in these eBooks

Info:

Periodical:

Solid State Phenomena (Volume 113)

Pages:

151-156

Citation:

Online since:

June 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] D. Karen, R. Gordon, D. Pardo, J. A. Johnson, J. Graham, W. King and T. A. Miller: Electromiographic activity and strength during maximum isometric pronation and supination efforts in healthy adults (Journal of Orthopedic Research, 22, 2004), pp.208-213.

DOI: 10.1016/s0736-0266(03)00115-3

Google Scholar

[2] S. L. Linstedt, P. C. LaStayo and T. E. Reich: When Active Muscle Lengthen: properties and consequences of eccentric contractions (News of Physiology Science, Vol. 16, 2001), pp.256-261.

DOI: 10.1152/physiologyonline.2001.16.6.256

Google Scholar

[3] M. Mariūnas, K. Kojelyt÷: Influence of muscle's fatigue to its biosignals' characteristics (Proceedings of the IASTED International Conference on BIOMECHANICS, August 23-25, 2004, Honolulu, Hawaii, USA. A Publication of the international association of Science and technology for development - IASTED, 2004), pp.80-85.

Google Scholar

[4] M. Mariūnas, K. Kojelyt÷: Research of finger muscle's stiffness dependence on loading conditions (Journal of Vibroengineering, Vol. 6, No 1, December 2004), pp.33-37.

Google Scholar

[5] M. Tarat, A. Spaepen and R. Puers: The accelerometerMMg measurement approach, in monitoring the muscular fatigue (Journal of Measurement Science Review, Vol. 1, No 1, 2001), pp.47-50.

Google Scholar

[6] D. J. Hewson, J. Y. Hogrel, Y. Langeron and J. Duchene: Evolution in impedance at electrodeskin interface of two types of surface EMG electrodes during long-term recordings (Journal of Electromyography and Kinesiology, Vol. 13, 2003), pp.273-279.

DOI: 10.1016/s1050-6411(02)00097-4

Google Scholar

[7] C. A. Shiffman, R. Aaron and S. B. Rutkove: Electrical impedance of muscle during isometric contraction (Journal of Physiological Measurement, Vol. 24, No 1, 2003), pp.213-234(22).

DOI: 10.1088/0967-3334/24/1/316

Google Scholar

[8] B. Elleby, L. F. Knudsen, B. H. Brown, C. E. Crofts, M. J. Woods and E. A. Trowbridge: Electrical impedance assessment of muscle changes following exercise (Journal of Physiological Measurement, Vol. 11, Issue 2, May 1990), pp.159-166.

DOI: 10.1088/0143-0815/11/2/006

Google Scholar

[9] T. Milner: Muscle-Tendon Mechanical Impedance http: /www. sfu. ca/~tmilner/aclb3. pdf.

Google Scholar

[10] L. Ten-Jen, H. Nishikawa: The variation of action potential and Impedance in human skeletal muscle during voluntary contraction (Journal of Experimental Medicine 1994), pp.303-09.

DOI: 10.1620/tjem.173.303

Google Scholar