Online since: March 2006
Authors: S.R. Sriraman, Hong Yan Zhang, Q.Y. Wang, S.L. Liu
The S-N data does not reach a horizontal asymptote at 10 7 cycles in either of the alloys.
The benefits of weight reduction and consequently, fuel saving, are important to the automotive industries.
The fatigue data of specially cast and heat-treated samples of magnesium alloys were found to be not representative of the behavior of actual cast components, unless cast under conditions similar to them.
Results and discussion The fatigue behavior (S-N data) for the alloys is presented in Figure 2.
While both the materials show a monotonic behavior in their fatigue characteristics, the variation in the S-N data of AM60 is gradual and much less steeper when compared with AE42. 20 40 60 80 100 120 1.
Online since: April 2019
Authors: Ali Asghar Firoozi, Ali Akbar Firoozi, Mohd Raihan Taha, Tanveer Ahmed Khan, Jamal M.A. Alsharef, Farzad Hejazi
The quality of mixing was assessed through intensity and scale of segregation using concentration data obtained through energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) analyses.
It was observed through these two tests that, increase in ball milling time after 6 hours resulted in grain size reduction.
Cui et al. [10] showed that the addition of carbon-nano tubes in concrete increases the hydration rates and stronger bonds build up between the carbon-nano tubes and the cement paste, while Petrunin et al. [11] recorded increase of 70% in the compressive strength of carbon-nano tubes reinforced concrete and reduction of 12% in the heat conductivity.
After 1, 2 and 6 hrs. of milling, the sample still contained the three forms of elemental powders, but with further milling (24 hrs.), peaks were reduced, showing that increasing ball mill time after 6 hrs. led to grain size reduction.
Online since: December 2012
Authors: Zhu Hong
Each image is composed of image data and noises, and it is described as Eq.1
(1) Where: is the primitive image data captured by X-ray, is the real image data without noises, and is the noise data.
The closer to 1 for , the better for the noise reduction.
The two chips are used to make 16bit data width for better calculation precision consideration, 16 frames can be processed in recursion.
For the 8bit grey level image, adding two 8bit data can generate data with 9 bits in width, if right shifted by 1 bit, meaning it is divided by 2, but the least significant bit gets lost, which results in calculation procession issue.
Online since: September 2014
Authors: Hai Qing Xu, Gui Ping Ruan
Our data and the analysis method are introduced in Section 2.
Observation and data reduction A series of observational data of the AR 11283 was provided by the SDO/HMI (Schou et al.2012[17]) and SDO/AIA (Lemen et al. 2012[18]) team.
Vector magnetic field data was taken by HMI.
HMI data is of 12 minute cadence for the 5 days from September 3-8 2011 and 0.5〞per pixel resolution.
Conclusions We have studied the non-potentiality of the magnetic field of AR 11283 using SDO/HMI and SDO/AIA data.
Online since: June 2013
Authors: Dyi Cheng Chen, Jiun Ru Shiu, Jheng Guan Lin
The data such as the Table 5.
Start training the original sample data which use the GANN.
Used to estimate the error of the validation data and forecasts) Unknown Number of data 1024(For all combinations of 5 factor 4 level) Table 6.
Validation data.
The bicycle the stem stress data informed by FEM simulation software.
Online since: April 2005
Authors: Qing Yuan Han, Ivan L. Berry, Carlo Waldfried, O. Escorcia, Brian White
The TDS data indicate that the moisture uptake of the He:H2 exposed films is quite small (< 2%) and only slightly higher than the control wafer.
The data indicates that the He:H2 strip does not cause appreciable changes of the k-value, which matches the moisture uptake data shown in Figure 1.
In general, CVD barrier data show big improvement in RC product compared to PVD barrier (POR).
From this data, the amount of low-k voiding does not correlate with early package level reliability failures.
TDS data indicate that the moisture uptake for the He:H2 treated films is very small.
Online since: July 2016
Authors: Lidia Benea, Alexandru Chiriac, Iulian Bounegru
A more complex equivalent circuit was necessary and proposed to fit the experimental EIS data of the Co/UHMWPE hybrid composite biocoatings (Fig. 4b).
Nyquist representation of EIS data for the tested surfaces in Hanks’ solution after 30 min from immersion.
The symbols represent experimental data for: (■) Co/UHMWPE (0 gL-1), (●) Co/UHMWPE (20 gL-1), (▲) Co/UHMWPE (30 gL-1).
Nyquist representation of EIS data for the tested surfaces in Hanks’ solution after 168 h from immersion.
The symbols represent experimental data for: (■) Co/UHMWPE (0 gL-1), (●) Co/UHMWPE (20 gL-1), (▲) Co/UHMWPE (30 gL-1).
Online since: October 2013
Authors: Li Wei Zhu, Yan Li, Lei Yang, Yun Peng Liu, Li Gao, Tao Zhao
But the reason for the reduction of the capacitor capacity is element through a larger current, which exceeds the predetermined value cause internal fuse blown.
The basic principle is to take can coil from the capacitor qualify to receive one side of the current energy through the follow-up to the rectifier, filter, regulator circuit processing power to the data acquisition module.
Synchronization of Data Acquisition and Wireless Network.
In order to meet the insulation requirements of the site, select the wireless data transmission by the high voltage side to the ground.
Data transmission takes the digital signal interference, high frequency communications and low error rate.
Online since: August 2018
Authors: Chobin Makabe, Md. Shafiul Ferdous, S.M. Moshiar Rahman
However, when the loading data is unknown, we should detect the variation of crack closure point by local strain.
In this study the acceleration and deceleration were obsereved depending on the conditions of overload or underload, in comparison with baseline data.
However, for the purpose of detecting a hazardous load when stress data is unknown, the strain functions were determined in this study.
It is shown in the present study that the detection can be carried out without the information of stress data.
Instead of stress data, we can use the data of strain function h1.
Online since: October 2008
Authors: Horia Mateiu, Alin Constantin Murariu, Traian Fleşer
For the remaining life assessment of the analyzed material after 60.000 hours and after was made the rehabilitate was used the expert system iRiS-Power [1] with the following modules: - iRiS- Material: data base with physical and mechanical characteristics of the materials including 16Mo5 steel, - iRiS-Creep: for the creep evaluation of the technical resistance for duration, - iRiS-Fatigue: for the resistance evaluation to fatigue at 773 K, - iRiS-TRD for the exhaustion creep evaluation to fatigue and remaining life.
For the low-cycle fatigue assessment in isotherm regime at 773 K from the data base of the iRiS-Material was utilized experimental data on the same kind of steel in different laboratories.
The remaining life assessment and creep-fatigue analyze - the final creep data - step3.
The failure conclusions to the remaining life - the final creep data - step3, on the creep tests results are presented in comparison with the TRD curves at 758 K, the creep fracture breaking curves experimentally determined on 34 samples from the reactor (ring 2 and 3) (figures 16 and 17).
[8] * * * ASTM E 739-06: Statistical analysis of linear or linearized stress-life (S-N) and strain-life (ε-N) fatigue data.