Online since: December 2011
Authors: Hai Quan Su, Yun Ma, Zhen Cao, Shi Yong Yu
Hydrogen evolved immediately, and the solution changed from pale pink to brown/ gray indicating the reduction of Co (II) into cobalt nanoparticles.
According to the data of product selectivity, it can be concluded that cobalt-based FT catalysts have higher selectivity and activity.
Online since: December 2009
Authors: Alessandra D'Epifanio, Elisabetta di Bartolomeo, Enrico Traversa, G. Balestrino, Emiliana Fabbri, Daniele Pergolesi, S. Licoccia
As expected on the basis of literature data, BCY decomposed in BaCO3 and CeO2, while BZY maintained a pure perovskite phase.
The reduction in conductivity was accompanied by an increase of Ea from 0.43 eV for the bilayer to 0.61 eV for BZY.
Online since: June 2012
Authors: Jing Guo, Xiao Ming Wang, Jiang Hua Xia
The current problems, if increase FFT length will need to add data storage, meanwhile, FFT transformation calculation logarithm growth, cannot achieve spectrum analysis of real-time, On the other hand, reduce the sampling rate, will affect AD the authenticity of sampling signal, which will severely affect shift frequency automatic block system reliability, and may even cause serious traffic accident.
It can’t avoid that the window effect in time domain lead to the peak of spectrum line and resolution of spectrum reduction, because that we can only process the finite signal samples.
Online since: September 2007
Authors: Chia Ching Chen, Nicolas G. Wright, Konstantin Vassilevski, Alton B. Horsfall
Values for the bulk material parameters for the two polytypes have been extracted from data given in the literature [4].
The dramatic reduction in the drain current indicates that the expected advantages from a heterojunction FET structures will not be realised at high temperatures where the electron density in the 2DEG is substantially reduced and these structures will be more suited to moderate temperature applications.
Online since: December 2011
Authors: Xiao Jian Zhang, Tian Ting Ding, Qiang Li
Corrosion-induced cracking: experimental data and predictive models, ACI Struct.
Prediction of reinforcement corrosion in concrete and its effects on concrete cracking and strength reduction, ACI Mater.
Online since: November 2005
Authors: Jung Hee Cho, J.W. Kim, K.S. Kim, W.Y. Lee, Sae Hoon Kim, Won Youl Choi
The drop image is grabbed and stored, via monochrome video camera, using a computer control, acquisition and data processing system.
This 38° reduction in contact angle shows that the surface wettability is increased.
Online since: March 2011
Authors: Cheng Yong Wang, Yue Xian Song, Lu Shu Wu, Hong Qun Tang, Jun Wen
The spindle speed will increase with the reduction of the diameter of drill.
Table 5 Experimental equipments Equipment Features Miniature Piezoelectric Force Sensor Range from 0 to 45N 8 Channel Data Acquisition System 16-bit resolution, USB interface High-speed video camera Speeds up to 20,000 fps PCB Drilling Machine Short stroke, high precision, Speeds up to 250 K rpm (a) Before experimental drilling (b) In drilling Fig.5 Pictures of high-speed video for drilling Results and discussions The relationship between cutting force and cutting time in simulation is shown in Fig.6 (a) and the relationship between cutting torque and cutting time in simulation is shown in Fig.6 (b).
Online since: July 2005
Authors: Zhi Min Zhang, Bao Hong Zhang, Qiang Wang
To data, most of Mg products have been fabricated through casting routes(1,2).
The second group bars with 92mm in diameter and 50mm in length were beforehand forged reduction to 10mm at 300℃.
Online since: January 2005
Authors: Zhi Yu Zhao, Wen Ji Xu, Jian Cheng Fang, L. Wang
Plasma jet generator Plasma jet Optical imaging system Interference filter Neutral density filter CCD A/D Imaging Data processing Smoothing processing Abel transformation Fake color processing Monitor Feedback control Fig.1 Collecting system for plasma jet Fig. 2 Plasma jet image Table 1 Collecting parameters of plasma jet and the corresponding experimental results No.
When the temperature of WC particle exceeds its melting point, an increase in particle velocity causes a higher hardness and a reduction in the porosity, which is the same to unmolten particle.
Online since: October 2011
Authors: Yu Lian Huang, Ming Lv, Guo Xing Liang, Gang Shi
When the excitation voltage from 2 V increase to 22 V, hysteresis torque increases to 31.77 from 11.91 cNcm, but when the excitation voltage is greater than the 18 V, linearity down significantly, the main reason is with the increase of excitation voltage, embedded coils increase in the role of magnetic energy resulting in hysteresis torque reduction.
From the experiment data, and to meet that hysteresis torque premise, with the lower range of excitation voltage, can raise tension control performance of the controller.