Effect of Saturation Degree on Concrete Deterioration due to Freeze-Thaw Action

Article Preview

Abstract:

Freezing-thawing durability of cement concrete is extremely important in cold weather, to better understand mechanism of frost damage and air-entraining,saturation degree of pores in concrete and its relation with frost resistance were studied in this paper. Concrete specimens with different saturation degree from 0 to 100% were prepared used a sealed tin with a high water pressure pump. Then these specimens were subjected to six freezing-thawing cycles and the relative dynamic modulus of elasticity was examined. The results showed that critical saturation degree of concrete with water- binder ratio of 0.30 and 0.47, air content of 1%, 4% and 6% were from 0.60 to 0.80. When its saturation degree exceeded the critical value, concrete was deteriorated significantly after only six freeze-thaw cycles. The critical saturation degree was mainly related to the air content of concrete mixture, and it decreased with the increasing of air content. The difference between the saturation degree and the critical value can be used to evaluate potential frost resistance of concrete, and its result was consistent with the result of frost tests very well.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

404-408

Citation:

Online since:

April 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Lars-Olof Nilsson. Interaction between Microclimate and Concrete-a Prerequisite for Deterioration. Construction and Building Materials. 1996, 10(5): 301~308.

DOI: 10.1016/0950-0618(95)00046-1

Google Scholar

[2] Lulu Basheer, Joerg Kropp, David J. Cleland. Assessment of the Durability of Concrete from Its Permeation Properties: a Review. Construction and Building Materials. 2001, 15: 93~103.

DOI: 10.1016/s0950-0618(00)00058-1

Google Scholar

[3] Michel Pigeon, Jacques Marchand, Richard Pleau. Frost resistant concrete. Construction and Building Materials. 1996, 10(5): 339~348.

DOI: 10.1016/0950-0618(95)00067-4

Google Scholar

[4] Stefan Jacobsen, Erik J. Sellevold and Seppo Matala. Frost Durability of High Strength Concrete: Effect of Internal Cracking on Ice Formation. Cement and Concrete Research. 1996, (26): 919~931.

DOI: 10.1016/0008-8846(96)00066-x

Google Scholar

[5] Vesa Penttala, Fahim Al-Neshawy. Stress and Strain State of Concrete during Freezing and Thawing Cycles. Cement and Concrete Research. 2002, 32: 1407~1420.

DOI: 10.1016/s0008-8846(02)00785-8

Google Scholar

[6] Josef P. Kaufmann. Experimental Identification of Ice Formation in Small Concrete Pores. Cement and Concrete Research. 2004, 34: 1421~1427.

DOI: 10.1016/j.cemconres.2004.01.022

Google Scholar

[7] S. Chatterji. Freezing of Air-entrained Cement-based Materials and Specific Actions of Air-entraining agents. Cement and Concrete Composites. 2003, 25: 759~765.

DOI: 10.1016/s0958-9465(02)00099-9

Google Scholar

[8] Lianxiang Du, Kevin J. Folliard. Mechanisms of Air Entrainment in Concrete. Cement and Concrete Research. 2005, 35: 1463~1471.

DOI: 10.1016/j.cemconres.2004.07.026

Google Scholar

[9] Kumar R, Bhattacharjee B. Porosity, pore size distribution and in situ strength of concrete. Cement and Concrete Research. 2003, 33: 155~164.

DOI: 10.1016/s0008-8846(02)00942-0

Google Scholar