Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior

Article Preview

Abstract:

In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world. In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior. For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program. As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined. The graphs and the data were compared and the results were discussed.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

45-49

Citation:

Online since:

March 2017

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Coffman HL, Marsh ML, Brown CB, (1993), Seismic Durability of Retrofitted Reinforced-Concrete Columns, J. Struct Eng-ASCE, 119, 5, 1643-61.

DOI: 10.1061/(asce)0733-9445(1993)119:5(1643)

Google Scholar

[2] Hamilton CH, Pardoen GC, Kazanjy RP, Hose YD, (2001), Experimental And Analytical Assessment Of Simple Bridge Structures Subjected To Near-Fault Ground Motions,. Structural Engineering, 2, 8.

DOI: 10.1016/b978-008043948-8/50110-7

Google Scholar

[3] Lehman D, Moehle J, Mahin S, Calderone A, Henry L, (2004), Experimental evaluation of the seismic performance of reinforced concrete bridge columns,. J Struct Eng- ASCE, 130, 6, 869-79.

DOI: 10.1061/(asce)0733-9445(2004)130:6(869)

Google Scholar

[4] Saatcioglu M, Baingo D, (1999), Circular high-strength concrete columns under simulated seismic loading,. J Struct Eng-Asce, 125, 3, 272-80.

DOI: 10.1061/(asce)0733-9445(1999)125:3(272)

Google Scholar

[5] Priestley MJN, Benzoni G, (1996), Seismic performance of circular columns with low longitudinal reinforcement ratios,. ACI Struct J, 93, 4, 474-85.

DOI: 10.14359/9706

Google Scholar

[6] SAP2000a Version 15, CSI Company, Berkeley, California, USA.

Google Scholar

[7] SAP2000b User Manual: CSI Company, Berkeley, California, USA.

Google Scholar

[8] FEMA 273/356, (1996), Federal Emergency Management Agency, Guidelines for the Seismic Rehabilitation of Buildings, Redwood City, California, USA.

Google Scholar

[9] TEC-2007, (2007), Turkish Code for the Seismic Design of Structures, Turkey.

Google Scholar

[10] Inel, M., Ozmen, H. B., (2008), Seismic performance evaluation of school buildings in Turkey, Structural Engineering and Mechanics, 30-5, 535-558.

DOI: 10.12989/sem.2008.30.5.535

Google Scholar