Optical Fiber CO Concentration Measurement Prism of the Gas Chamber Variable Optical Path Automatic Adjustment System Research

Article Preview

Abstract:

According to the absorption spectrum, combined with CO distribution feedback type laser diode (DFB-LD) light source, we selected R a center for 1567.3 nm as the wavelength of the absorption spectrum line. Comprehensively using of prism of gas chamber and harmonic detection technology, we constructed the optical fiber CO concentration measurement system. Through the stepping motor regulation height, it changes indoor prism gas effective absorption process, adjusts the light sensitivity system.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

237-243

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] GUAN Zhong-hui, HE Yu-kai, LIU Zhong-qi. Detection of Carbon Monoxide Gas in Coal Mine. Mining Machinery, 2006, (5): 21-23.

Google Scholar

[2] SUN Ji-ping. Arrangement of Gas, Carbon Monoxide and Temperature Sensors in Mine. Coal Science and Technology 2000, (1): 44-46.

Google Scholar

[3] Joel A. Silver. Frequency-modulation Spectroscopy for Trace Species Detection Theory and Comparison among Experimental Methods. Applied Optics, 1992, 31(6): 707.

DOI: 10.1364/ao.31.000707

Google Scholar

[4] J. Reid, D. Labrie. Second-Harmonic Detection with Tunable Diode Lasers–Comparison of Experiment and Theory. Applied Physics. 1981, B26: 203.

DOI: 10.1007/bf00692448

Google Scholar

[5] WU Jing. Overview of Designing Gas Chamber of Absorption Fiber-Optic Gas Sensors [J]. China High Technology Enterprises, 2009, 13: 18.

Google Scholar

[6] Miha Zavrs nik, George Stewart. Theoretical Analysis of a Quasi-distributed Optical Sensor System Using FMCW for Application to Trace Gas Measurement [J]. Sensors and Actuators, 2000, B71 (1-2): 31~35.

DOI: 10.1016/s0925-4005(00)00587-6

Google Scholar

[7] YU Hong-bo, LIAO Yan-biao, LAI Shu-rong etc. Optical Fiber Gas Sensor Network with Intracavity Spectroscopy [J]. China Laser, 2003, 30 (2): 154 - 158.

Google Scholar

[8] Gillian Whitenett, George Stewart, Hongbo Yu etc. Investigation of a Tuneable Mode-locked Fiber Laser for Application to Multipoint Gas Spectroscopy [J].J. Lightwave Techol., 2004, 22(3): 813~819.

DOI: 10.1109/jlt.2004.824530

Google Scholar

[9] WANG Shi-mei, LIU Wen-qing, LIU Jian-guo, etc. The Study of Remote Sensing CH_4 Concentration Based on Tunable Diode Laser Absorption Spectroscopy, Spectroscopy and Spectral Analysis, 2006, 26(2): 221.

Google Scholar

[10] XIAO Shao-Rong, GAO Zhi-shan. Application of Gas Sensor Based on Rectangular Prism in the Monitoring of Atmospheric Visibility, China laser, 2006. 1: 1.

Google Scholar