Research of Reliability on the Switch Phase-Sensitive Circuit of the Equipment
Abstract:
The transformer is the hard core of the switch phase-sensitive circuit of the equipment. According to the basic failure rate model and working failure rate model of the national standards, the transformer working reliabilities are analyzed under different working conditions and environments. Based on this, the reliability analyses of the redundancy structures of the switch phase-sensitive circuit are done, and the comparisons and analysis of the results are done, and the useful conclusions for design and engineering are presented.