Volume Concentration and Phase Distribution Measurement of Pulverized Coal in the Pneumatic Conveyor

Article Preview

Abstract:

This paper proposed the design and experimental evaluation of a radiometric instrumentation system which was developed for measuring the volume concentration and phase distribution of pulverized coal in a pneumatic conveying pipeline.The system employed point γ-ray source with 180° plane angle of emergence source collimator, γ-ray detector multi-element independent each other annular arrayed out of the sensor conduct wall,every detector element was standardized singly,in order accommodate the inhomogeneity of the pulverized coal distribution in the pipeline.the instrument system would be able to determine the volume concentrition independently of the flow pattern while obtain the distribution information of pulverized coal in the conveying pipeline cross section. The static experment improved that the solution was correct in principle.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2729-2732

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Y. Yan: Mass flow measurement of bulk solids in pneumatic pipelines. Measurement Science and Technology, 1996, 35(7), 1687~1706.

DOI: 10.1088/0957-0233/7/12/002

Google Scholar

[2] I. R. Barratt, Y. Yan, B. Byrne, M.S.A. Bradley: Mass flow measurement of pneumatically conveyed solids using radiometric sensor. Flow Measurement and Instrumentation, 11(2000) 223-235.

DOI: 10.1016/s0955-5986(00)00022-4

Google Scholar

[3] Duan Quansheng: Study on pulverized coal volume concentration and distribution measurement in the pneumatic conveyor. Doctoral dissertations, Beijing: North Electric Power University , 2010. 3.

Google Scholar

[4] Ji Changsong: Nuclear radiation detector and experiment technical manuals. Beijing: Atomic Energy Press, 1990, 10.

Google Scholar