Dynamic Response of Ceiling System with Light Steel Furring and Gypsum Board under Severe Earthquake

Article Preview

Abstract:

In order to make sure reliability of ceiling system according to the current code, response acceleration of ceiling suspension points are obtained by seismic model developed by ANSYS/LS-DYNA. Then the FE model of ceiling system according to the current code is also developed in ANSYS/LS-DYNA. The input acceleration is added on ceiling suspension point. The following features are obtained from ceiling system with light steel furring and gypsum board under severe earthquake. These are: 1 Many gypsum boards which are designed according to the current code are failed and drop down,that may result in casualties. 2 The furrings are failed and did not drop down, then may drop for higher peak acceleration. 3 The ceiling system according to the current code is not safe under severe earthquake.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2221-2225

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Pera Global (Beijing) Limited Company.ANSYS /LS-DYNA user's guide [M]. Beijing: Pera Glabal (Beijing) Limited Company, 1999. (In Chinese)

Google Scholar

[2] China institute of building standard design research.Technical specification for installation of ceiling systems in buildings [M]. Beijing: China plans to press, 2009. (In Chinese)

Google Scholar