Research on Techniques and Experiments of Electrostatic Radon Elimination in Underground Engineering

Article Preview

Abstract:

The research status of radon elimination techniques at home and abroad in recent years is introduced. The feasibility of electrostatic radon elimination in underground engineering is analyzed. The technical problems of reducing radon and its daughters and such harmful substances are analyzed. The type of cellular and flat field dual-zone in electrostatic radon elimination is investigated. The dual-zone radon elimination equipment is designed and related tests are done.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1690-1695

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Xiaogong Jin. The research of mitigating radon pollution in National defense[D].Nanjing, Engineering Institute of Corps of Engineers,PLA Univ. of Sci. & Tech.2009. In Chinese.

Google Scholar

[2] T. Streil S. Exploration of radon affected work and living places and methods for the reduction of the radon exposure

Google Scholar

[3] Daniel J. Steck. Risks From a Radon Decay Product Standpoint. Conference of Radiation .Program Director's 14th National Radon Meeting

Google Scholar

[4] Renchang Le, Qingcheng Liu. The research of radon migration mechanism and law. [J]. Measurement and evaluation of Rn/Tn in the environment. International Symposium on Assembly. pp.39-43

Google Scholar