Cause Analysis and Countermeasures of Emulsified Explosive Misfire in Vertical Shaft Frozen Zone Excavation Blasting
Abstract:
Emulsion explosive have well frost resistance, it can be stably detonated at -300C. But there are many misfires occurred in blasting construction of shaft frozen zone. After analysis, the causes was water in the hole frozen and it’s volume increased, so explosive cartridge was pressed, it’s density enlarged, and misfire created when it’s density exceed critical density of stable detonation. Based on analysis, plastic tube casing charge adopted for construction, and prevent misfire effectively.
Info:
Periodical:
Pages:
3046-3049
Citation:
Online since:
May 2012