Analysis on the Seismic Behavior of Extended End-Plate Connections of Steel Frame Structure

Article Preview

Abstract:

This paper conducts analysis on beam-column extended end-plate semi-rigid connection joint concerning monotonic loading and cyclic loading of finite element through ANSYS program, mainly discussed the influence of parameters such as the form of end plate stiffening rib on anti-seismic performance of joint.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1405-1413

Citation:

Online since:

August 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Chen Huifa. Stabilized design of steel framework [M]. Shanghai: World Publishing Corporation,(1999)

Google Scholar

[2] Guo Bing, Gu Qiang, Liu Feng, Zhao Kaochong. Study on hysteresis performance experiment of beam column end plate connection joint. Journal of Building Structural [J]. 2002,23(3)

Google Scholar

[3] Shang Yuejin. Theory of infinite element and ANSYS application guide [M]. Tsinghua University press 2005,1

Google Scholar

[4] Ren Zhong. ANSYS practical analysis course [M]. Peking University press, 2003,1

Google Scholar

[5] Tarpy T S, Cardinal J W. Behavior of Semi-rigid Beam-to-Column End-Plate Connections. In:Howlett J H,Jenkins W M,Stainsby R.Joints in Structural Steelwork. London: Pentech Press,1981;

Google Scholar

[6] Jenkins W M,Tong G S,Prescott A T.Moment-transmitting end-plate connections in Steel construction and a proposed basis for flush end-plate design. The Structural Engineer,1986,64A(5);

Google Scholar

[7] Aggarwal A K. Comparative Tests on Endplate Beam- to- Column Connections, Journal of Constructional Steel Research,1994,30;

DOI: 10.1016/0143-974x(94)90048-5

Google Scholar

[8] Tsai K C, Popov E P. Cyclic Behavior of End-Plate Moment Connections. Journal of Structural Engineering,1990,116(11);

DOI: 10.1061/(asce)0733-9445(1990)116:11(2917)

Google Scholar

[9] Adey B T, Grondin G Y, Cheng J J R. Cyclic Loading of End- Plate Moment Connections. Canadian Journal of Civil Engineering,2000,27(4);

DOI: 10.1139/l99-080

Google Scholar

[10] Shi Gang. Study on static and earthquake resistance performance of steel framework semi-rigid end plate connection [D], Tsinghua University, (2004)

Google Scholar

[11] Zhao Wei. Study on some problems occurred in the connection of beam column overhanging end plate bolt [D], Zhejiang University, (2006)

Google Scholar

[12] JGJ101-96[S]. Regulation of building seismic test method, Beijing, (1977)

Google Scholar

[13] GB50017-2003[S]. Design specification of steel structure

Google Scholar

[14] GB50011-2001[S]. Design specification of earthquake resistance

Google Scholar

[15] JGJ82-91[S].Design, construction and acceptance regulation on steel structure high strength bolt connection.

Google Scholar