Research on the Mechanical Properties of Fire-Damaged Reinforced Concrete Columns Strengthened with CFRP

Article Preview

Abstract:

The mechanical properties of fire-damaged reinforced concrete columns rehabilitated by carbon fiber-reinforced polymer (CFRP) rods were studied. This study aims at the effectiveness of CFRP through the contrast test. Nine specimens were tested, including three normal temperature control specimens, and six specimens heated under ISO834 standard fire. After the specimens were exposed to fire, three of them were rehabilitated by CFRP. All specimens were loaded monotonically to failure in the same way. The results showed that the failure of reinforced concrete columns rehabilitated by CFRP was due to losing stabilization, whereas the others were material broken. Furthermore, because of the fire, the load-bearing capacity of specimens was all declined sharply compared with these at normal temperature. From this research, comparing with these normal temperature control specimens, the load-bearing capacity of specimens exposed to fire firstly was ranged from 0.25 to 0.37 times. But the ratio of the loading capacity of specimens rehabilitated by CFRP and normal temperature control ones was ranged from 0.54 to 0.67.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1429-1435

Citation:

Online since:

August 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yao Jian. Research advance in FRP-strengthened RC structures. Bulletin of Science and Technology, Vol. 20-3(2004), pp.216-221. (in Chinese).

Google Scholar

[2] Yu Qiong, Lu Zhoudao. Research on the static performance of RC eccentric column strengthened with circumferential FRP (I). Sichuan Building Science, Vol. 35-5(2009), pp.49-53. (in Chinese).

Google Scholar

[3] Mohamed Hussein and Tarek M. Fawzy. Structural performance of CFRP-strengthened RC slabs in a corrosive environment. Journal of Composites for Construction, Vol. 14-6(2010), pp.865-869.

DOI: 10.1061/(asce)cc.1943-5614.0000133

Google Scholar

[4] Azadeh Parvin, Selcuk Altay, Cem Yalcin and Osman Kaya. CFRP rehabilitation of concrete frame joints with inadequate shear and anchorage details. Journal of Composites for Construction, Vol. 14-1(2010), pp.72-82.

DOI: 10.1061/(asce)cc.1943-5614.0000055

Google Scholar

[5] Xu Zhisheng, Feng Kai, Zhang Weizhen. Experimental analysis of CFRP used to strengthen RC beam after fire. Journal of Harbin Institute of Technology, Vol. 37-1(2005), pp.98-100. (in Chinese).

Google Scholar

[6] Li Yaozhuang, Tang Yijun. Experiment study and function reliability analysis on RC continuous beam subject to high temperature and strengthened with CFRP sheets. Fire Safety Science, Vol. 14-4(2005), pp.234-238. (in Chinese).

Google Scholar

[7] Xiang Kai, Yu Jiangtao, Lu Zhoudao, Gao Jinchun. Experimental research on carbon fiber reinforced polymer sheets strengthed fire-damaged reinforced concrete continuous beams. Journal of Sichuang University (Engineering Science Edition), Vol. 42-2(2010).

DOI: 10.1109/icetce.2011.5774655

Google Scholar

[8] Wang Liguo, Lu Zhoudao, Sheng Qianzhu. Experimental research on pre-stressed concrete frame after high temperature rehabilitated by CFRP. Fire Safety Science, Vol. 12-4(2003), pp.218-223. (in Chinese).

Google Scholar

[9] Williams B K. Fire performance of FRP-strengthened reinforced concrete flexural members, 2004(in Canada).

Google Scholar

[10] Kodur V K R, Bisby L A, Green M F. Preliminary guidance for the design of FRP-strengthened concrete members exposed to fire. Journal of Fire Protection Engineering, Vol. 17-1(2007), pp.5-26.

DOI: 10.1177/1042391507061956

Google Scholar

[11] Gao Wangyang, Hu Kexu, Lu Zhoudao. Fire resistance experiments of insulated CFRP strengthened reinforced concrete beams. China Civil Engineering Journal, Vol. 43-3(2010), pp.15-23. (in Chinese).

Google Scholar