Laminated Composite Beam with Bonded CFRP Reinforcement Stress Performance Analysis

Article Preview

Abstract:

Based on the test of 7 reinforced concrete beam reinforcement test data comparison analysis shows that only the ordinary reinforced concrete beams with externally bonded CFRP, effectively improve the bearing capacity of members, but due to the lower tensile reserves and the upper compression reserve is relatively insufficient, make a component similar over-reinforced beam brittle failure, its ultimate bearing capacity was significantly lower than the upper part at the same time a laminated layer of the RC beam. Laminated paste CFRP composite reinforced RC beam damage characteristics and common reinforced concrete beam was no essential difference, but the laminated layer thickness reaches to a certain degree, the CFRP can also occur with sudden local cleavage fracture.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3160-3163

Citation:

Online since:

October 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] JTG B01-2003, technIcal standard of hIghway engIneerIng [S], BeIjIng, ChIna CommunIcatIons Press, 2004.

Google Scholar

[2] CECS146-2003, carbon fIber sheet reInforced concrete structure [S], BeIjIng, ChIna PlannIng Press, 2003.

Google Scholar

[3] Law of the People's RepublIc of ChIna MInIstry of constructIon, GB50152-90 test methods of concrete structures [S], BeIjIng, ChIna BuIldIng Industry Press, 1992.

Google Scholar