Abstract:

Appling urban untreated sewage as a cool and heat source of the heat pump air conditioning system is considered to be an effective way to develop urban sewage resource and a critical technique to serve the building energy system.Applications of technical difficulties are to solve the jam on sewage dirt to tube of heat exchanger and pipes. The multi-filter surface backwash technology is used to separate the suspended solids from the sewage and clean the dirt on the grille. By describing the filtration technique in the sewage source heat pump system to introduce the principle of operation and control process of the multi-filter surface backwash technology. By using in commercialese, the technology is proved to be feasible and reliability. These methods could serve as a reference for designing and application untreated sewage source heat pump systems.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

4378-4383

Citation:

Online since:

October 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Fengqi Zhou. Challenge posed to China's energy industry in the 21st century. HV&AC. Vol.30, 2000.4st.p.23~25.

Google Scholar

[2] N.C. Baek, U.C. Shin, J.H. Yoon. A study on the design and analysis of a heat pump heating system using wastewater as a heat source. Solar Energy. 78(2005).p.427~440.

DOI: 10.1016/j.solener.2004.07.009

Google Scholar

[3] Ronghua Wu, Dexing Sun, Chenghu Zhang, Guangxing Ma. Application and progress of urban wastewater as a cool and heat source. Journal of harbin institute of technology. Vol.38.No.8.Aug.2006.p.1326~1329.

Google Scholar

[4] Yong Cho, Rin Yun. A Raw water source heat pump air-conditioning system. Energy and Buildings.43 (2011).p.3068~3073.

DOI: 10.1016/j.enbuild.2011.07.028

Google Scholar

[5] X.L. Zhao, L.Fu, S.G. Zhang, Y. Jiang, Z.L. Lai. Study of the performance of an urban original source heat pump system. Energy Conversion and Management. 51(2010).p.765~770.

DOI: 10.1016/j.enconman.2009.10.033

Google Scholar

[6] Ronghua Wu, Ying Xu, Dexing Sun, Nanqi Ren. Research and utilization progress of intake water heat-exchange technique of sewage and surface water source heat pump system. HV&AC.Vol.38 (2008), 3st.p.25~29.

Google Scholar

[7] Weijia Zhang, Dalin Pan. Engineering Fluid Mechanics. Heilongjiang science &technology press. 2001.pp.66-68.

Google Scholar