The Effect of Previous Exposure Temperature on People’s Perception in Semi-Outdoor Spaces

Article Preview

Abstract:

Past thermal experience is related to the memory and seems to be responsible for the changes in people’s expectations. In order to investigate how the previously air conditioned exposure impacts thermal perception in semi-outdoor spaces, the controlled experiments were conducted, with a total of 36 undergraduates who participated as the subjects. Based on the controlled experiments, the impact of previous exposure temperature to air conditioning was examined. It was found that the previously air conditioned exposure temperature has impact on thermal perception in semi-outdoor spaces. Based on the experiments, it can be found that the impact of the air conditioned exposure temperature is not significant when the temperature difference between the air conditioned environments is about 2°C or 3°C. However, the impact of the air conditioned exposure temperature appears significant when the temperature difference between the air conditioned environments is up to 5°C.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

256-259

Citation:

Online since:

October 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] de Dear, R.J. and Brager, G..The adaptive model of thermal comfort and energy conservation in the built environment. International Journal of Biometerorol, 45, 100-108. (2001)

DOI: 10.1007/s004840100093

Google Scholar

[2] ASHRAE. ASHRAE Standard 55-2004, Thermal environmental conditions for human occupancy. American society for heating, ventilating, refrigeration and air- conditioning engineers, Atlanta. (2004)

Google Scholar

[3] Baker, N. Comfort in passive buildings. Proceedings of Solar Energy and Buildings, Academy of Athens. (1993)

Google Scholar

[4] Hawkes, D. and Willey, H. User response in the environment control system. Transactions of the Martin Center for architectural and urban studies, Vol. 2, Cambridge. (1977)

Google Scholar

[5] de Dear, R.J. Thermal comfort in air-conditioned office buildings in the tropics. Standards for thermal comfort: indoor air temperature standards for the 21st centry, Chapman and Hall, London. (1995)

DOI: 10.1016/0140-6701(96)87138-4

Google Scholar

[6] Griffiths, I.D. and Willey, H. (1987). User response in the environment. Proceedings of the 1987 European conference on architecture, Kluwer Academic Publishers for the Commission of the European Communities, Netherlands.

Google Scholar

[7] Givoni, B. Climate considerations in building and urban design. Van Nostrand Reinhold, New York. (1998)

Google Scholar

[8] Baker, N. and Standeven M. Thermal comfort for free-running buildings. Energy and Buildings, 23, 175-182. (1996)

DOI: 10.1016/0378-7788(95)00942-6

Google Scholar