Abstract:

The special-shaped concrete-filled steel tubular column (SCFST column) is recognized to have high bearing capacity and good fire resistance. This paper introduced a nonlinear FEA approach to analysis the temperature field of SCFST under standard ISO-834 fire condition. Finite element model was built with nonlinear material properties elements in ANSYS; thermal boundary conditions were applied to the model with convection and radiation combined to simulate the fire condition, and several conclusion were obtained from the nonlinear FEA results.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

980-985

Citation:

Online since:

November 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zhihua Chen, Ting Zhou and Xiaodun Wang, in:Application of Special Shaped Column Composed of Concrete-filled Steel Tubes,Advanced Materials Research,2011.

DOI: 10.4028/www.scientific.net/amr.163-167.196

Google Scholar

[2] Ting Zhou, Zhihua Chen and Hongbo Liu,in:Nonlinear Finite Element Analysis of Concrete-filled Steel Tubular Column, 2011 International Conference on Electric Technology and Civil Engineering (ICETCE), 2011.

DOI: 10.1109/icetce.2011.5774351

Google Scholar

[3] Linhai Han and Xiaokang Lin, in: Tests on Cyclic Behavior of Concrete-FilledHollow Structural Steel Columns after Exposure to the ISO-834 Standard Fire, Journal of Structural Engineering,2004.

DOI: 10.1061/(asce)0733-9445(2004)130:11(1807)

Google Scholar

[4] Amit H. Varma, JarupatSrisa-Ard and Sangdo Hong, in: Analytical Investigations of the Fire Behavior of Concrete Filled Steel Tube(CFT) Columns, Structures, 2004.

DOI: 10.1061/40700(2004)125

Google Scholar

[5] Linhai Han and Xiaokang Lin, in:Effects of Sustained Load on Concrete-Filled Hollow Structural Steel Columns, Journal of Structural Engineering, 2004.

DOI: 10.1061/(asce)0733-9445(2004)130:9(1392)

Google Scholar

[6] Linhai Han, Jingsi Huo and Yong-Chang Wang, in:Behavior of Steel Beam to Concrete-Filled Steel TubularColumn Connections after Exposure to Fire,Journal of Structural Engineering, 2007.

DOI: 10.1061/(asce)0733-9445(2007)133:6(800)

Google Scholar

[7] Linhai Han, Xiaoling Zhao et al., in: Experimental Study and Calculation of Fire Resistance of Concrete-Filled Hollow Steel Columns, Journal of Structural Engineering, 2003.

Google Scholar

[8] Lisa Choe, Amit H. Varma et al., in: Fundamental Behavior of Steel Beam-Columns and Columns under Fire Loading: Experimental Evaluation, Journal of Structural Engineering, 2011.

DOI: 10.1061/(asce)st.1943-541x.0000446

Google Scholar

[9] Jian-Feng Chen and Ping-Zhou Chao, in: Numeric Simulation of Temperature Field on Steel Connections in Fire, Building Science, 2008.

Google Scholar

[10] Hang Zhu and Ying-huiFeng, in: Numerical Analysis on Temperature Distribution in Steel Reinforced Concrete Columns Against Fire, Zhejiang Construction, 2011.

Google Scholar