The Research of Glucose Solution Based on Photoacoustic Measurement

Article Preview

Abstract:

Based on the principle of photoacoustic,blood glucose can be non-invasive monitoring of in the NIR region.The system irradiates to the glucose solution by opo laser,then the signals are received by photoacoustic probe and processed by the oscilloscope, finally imported into the computer.By the least squares method,the data repeatedly fits to make the mean square error of the glucose concentration less than 5mg/dl.The experimental results show that:photoacoustic measurement method can achieve a certain precision, with the value of further research.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

27-31

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Rosencwaig A. Photoacoustics and photoacoustic spectroscopy[M].New York:Wiley,94-120. (In Chinese)

Google Scholar

[2] Zhang S Y,Wang Z Q,Cheng J C,et al.Mechanisms,techniques and applications of photoacoustic effect in semiconductors[J],Progress Nat Sci,1994,4:201-210.

Google Scholar

[3] Liu ZHiping,Shi Linying,The principle of least square algorithm and its achievement by matlab[J].Science and technology of west China.2008 7(17):33-34.

Google Scholar

[4] Huang Ze,Chen Lanpin,Wang Feng.Numerical Analysis.Science Press.2004,3.

Google Scholar

[5] Diebold GJ & Sun T (1994) Properties of photoacoustic waves in one, two, and three dimensions. Acustica 80: 339–351.

Google Scholar

[6] Matti Kinnunen Comparison of optical coherence tomography ,the pulsed photoacoustic technique,and the time of flight technique in glucose measurements in vitro.

Google Scholar

[7] Zhao Z, Nissilä S, Ahola O & Myllylä R (1998) Production and detection theory of pulsed photoacoustic wave with maximum amplitude and minimum distortion in absorbing liquid. IEEE Transactions on Instrumentation and Measurements 47: 578–583.

DOI: 10.1109/19.744208

Google Scholar

[8] G.B. Christison H.A. Mackenzie.Laser photoacoustic determination of physiological glucose concentration in human whole blood..Med &Biol.Eng.&Comput,1993.31,284-290.

DOI: 10.1007/bf02458048

Google Scholar

[9] Jussi T,Harri K,Risto M.Non-invasive measurement of glucose using near infrared spectroscopy[J].Pittcon 1998,3:1-5.

Google Scholar

[10] Li Qingbo,Zhang Lu,Wang Yan,Hu Xiaotang,Xu Kexin.Near-infrared spectroscopic measurement of glucose concentrations in an aqueous matrix-fundamental study on noninvasive measurement method of human blood glucose concentration.Chinese journal of biomedical engineering,2004,602-606.

Google Scholar

[11] Kevin H.Hazen Mark A.Arnold,Gary W.Small.Temperature-Insensitive Near-Infrared Spectroscopic Measurements of Glucose in Aqueous Solutions[J].Applied Spectroscopy, 1994,48(4):477-483.

DOI: 10.1366/000370294775268910

Google Scholar

[12] Kevin H.Hazen Mark A.Arnold,Gary W.Small.Measurements of Glucose in Water with first -overtone Near -Infrared Spectra[J].Applied Spectroscopy,1988,52(12):1579-1605.

DOI: 10.1366/0003702981943103

Google Scholar

[13] Mark A.Amold,Gary W.Small.Determination of physiological Levels of Glucose in an Aqueous Matrix with Digitally Filtered Fourier Transform,Near-Infrared Spectra[J].Analytical Chemistry,1990,62(14):1457-1464.

DOI: 10.1021/ac00213a021

Google Scholar