A Complex Voltage Ratio Measurement System for the Audio Frequency Range

Article Preview

Abstract:

This paper describes the setup of a complex voltage ratio measurement system for the audio frequency range. A wideband two-channel digitizer and a differential analogue channel switching front-end are used as the heart of the system. The complex error, frequency response characteristics and short term stability of the system are tested in this paper. The errors range from 1×10-7 at 50 Hz to 10×10-6 at 200 kHz in ratio 1:1 test with 6 V input voltages. And errors are below ±8×10-7 and ±0.06 μrad in ratio 1:1 test with a 4V power line (50 Hz) input voltage over 64 hours. The test results and comparisons between with and without channel exchange mode confirm the remarkable improvement regarding the suppression of the static mismatch errors of the digitizer and show the usefulness of the system at 50 Hz too.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

278-282

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] BAI Hong-bin, WANG Rui-hong. Influence of the Grid-connected Wind Farm on Power Quality [J]. Proceedings of the CSU-EPSA, 2012, 24(1): 120-124.

Google Scholar

[2] YUE Guo-yi, DUAN Xiao-bo, GENG Jian-po. Electric Energy Measurement Research of Harmonics of Power Supply for Electrified Railways [J], Electrical Measurement & Instrumentation, 2009, 46(524): 39-43.

Google Scholar

[3] Gu Hongbo, Wu Hongbin, Wang Yu. The research on a novel com parator-type instrum ent transformer calibrator [J]. Electrical Measurement & Instrumentation, 2003, 40(456): 20-23.

Google Scholar

[4] LI Dong-fang, YANG Zhi-feng. Type HEW2001 Digital Direct-reading Transformer Calibrator with Multi-function [J]. Journal of Taiyuan Heavy Machinery Institute, 2001, 22(3): 243-246.

Google Scholar

[5] W. G. Kuerten Ihlenfeld. Traceability of AC Voltage Ratios and AC Power by Synchronous Digital Synthesis and Sampling. PTB-Bericht E76, (2001).

Google Scholar

[6] Waldemar G. Kuerten Ihlenfeld, Enrio Mohns, M. Serra, Kristian Dauke, and Andreas Suchy. Quasi-Synchronous Microcontroller-Based Highly Accurate Digital Sampling of AC Signals [J]. IEEE Transactions on Instrumentation and Measurement, 2007, 56(2): 414-417.

DOI: 10.1109/tim.2007.891039

Google Scholar

[7] NI 5922 Digitizer Specification Manual. Available at: www. ni. com.

Google Scholar

[8] E. Mohns. Instrumentation Amplifiers with Improved Accuracy for the Audio Frequency Range. Conf. Digest CPEM (2012).

Google Scholar

[9] E. Mohns, C. Yue, F. Zhou, T. Moehring, and M. Schmidt. A Current Transformer Bridge for the Audio Frequency Range. Conf. Digest CPEM (2012).

Google Scholar

[10] T. Moehring, E. Mohns and M. Schmidt. Characterisation Digitizer with an Analogue Differential Front-end. Conf. Digest CPEM (2012).

Google Scholar

[11] Enrio Mohns and Martin Kahmann. Heterodyne Measurement system (HMS) for Determining Phase Angles [J]. IEEE Transactions on Instrumentation and Measurement, 2007, 56(2): 505-508.

DOI: 10.1109/tim.2007.890624

Google Scholar