Semi-Automated Computer Analysis of Retinal Vessels in Premature Infants

Article Preview

Abstract:

Almost all ocular and systemic diseases affect blood vessel attributes (tortuosity, length, width, and curvature). Quantitative measurements of these attributes could thus provide useful tool for diagnosing the severity of several diseases. However, it is still unclear how best to represent the attribute values of multiple vessels in a single image. Graphical user interface (GUI) is a promising step towards the development of a semi-automated computer assisted tool. The objective of this study is to develop a GUI for effective observation and robust retinal blood vessels analysis by ophthalmologists and to comprehend the distribution of vessels attributes. Blood vessels from 45 digital fundus images of infant retina are extracted, its centerline is delineated and tortuosity is analyzed from different putative and proposed techniques to provide reliable and comprehensive information for the retinal vasculature. K means clustering technique is used for classification analysis of different tortuosity metrics and its performance is evaluated based on sensitivity, specificity, and accuracy. The results are validated by comparing with expert ophthalmologists’ ground truths. Among the various proposed tortuosity metrics, one of our tortuosity indexes attains the highest classification accuracy of 91.42% with sensitivity and specificity of 86.36% and 97.82% respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2962-2968

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wallace DK, Zhao Z, Freedman SF, A pilot study using ROPtool, to quantify plus disease in retinopathy of prematurity. J AAPOS2007; 11(4): 381-387.

DOI: 10.1016/j.jaapos.2007.04.008

Google Scholar

[2] Henegan C, Flynn J, O'Keefe M, et al. Characterization of changesin blood vessel width and tortuosity in retinopathy of prematurity using image analysis. Med Image Anal. 2002; 6(4): 407– 429.

DOI: 10.1016/s1361-8415(02)00058-0

Google Scholar

[3] Swanson C, Cocker KD, Parker KH, et al. Semiautomated computer analysis of vessel growth in preterm infants without and with ROP. Br J Ophthalmol. 2003; 87(12): 1474–1477.

DOI: 10.1136/bjo.87.12.1474

Google Scholar

[4] Gelman R, Martinez-Perez ME, Vanderveen DK, et al. Diagnosis of plus disease in retinopathy of prematurity using Retinal Image multiScale Analysis. Invest Ophthalmol Vis Sci. 2005; 46(12): 4734-4738.

DOI: 10.1167/iovs.05-0646

Google Scholar

[5] Lassada Sukkaew, Bunyarit Uyyanonvara, Sarah Barman, Alistair Fielder, Ken Cocker, Automatic extraction of the structure of the retinal blood vessel network of premature infants, Journal of Medical Association of Thailand , Vol. 90, No. 9, 2007, pp.1780-1792.

Google Scholar

[6] Lassada Sukkaew, Bunyarit Uyyanonvara, Stanislav S. Makhanov, Sarah Barman, and Pannet Pangputhipong, Automatic Tortuosity- Based Retinopathy of Prematurity screening system, IEICE Trans. INF. & SYST., VOL. E91-D, NO. 12 DECEMBER (2008).

DOI: 10.1093/ietisy/e91-d.12.2868

Google Scholar

[7] Venkatalakshmi, B., Saravanan, V. and Niveditha, G.J., Graphical User Interface for enhanced retinal image analysis for diagnosing diabetic retinopathy, Communication Software and Networks (ICCSN), 2011 IEEE 3rd International Conference, pp.610-613, (2011).

DOI: 10.1109/iccsn.2011.6014967

Google Scholar

[8] Kee Yong Pang, Lila Iznita I, Ahmad Fadzil M H, Hanung A. N., Hermawan N. and Vijanth S A, Segmentation of Retinal Vasculature in Colour Fundus Images, Innovative Technologies in Intelligent Systems and Industrial Application 2009 (CITISIA 2009), pp.398-401, (2009).

DOI: 10.1109/citisia.2009.5224176

Google Scholar

[9] Delori et al (2001): "Macular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry. J. Opt. Soc. Am. 18: 121230.

DOI: 10.1364/josaa.18.001212

Google Scholar

[10] Danu Onkaew, Rashmi Turior, Bunyarit Uyyanonvara, Nishihara Akinori, Chanjira Sinthanayothin, Automatic Retinal Vessel Tortuosity Measurement using Curvature of Improved Chain Code, International Conference on Electrical, Control and Computer Engineering (InECCE 2011), pp.183-186.

DOI: 10.1109/inecce.2011.5953872

Google Scholar

[11] Rashmi Turior, Danu Onkaew, Toshiaki Kondo, Bunyarit Uyyanonvara, A novel approach for quantification of retinal vessel tortuosity based on principal component analysis, Proceeding of 8th Electrical Engineering/Electronics, Computer, Telecommunication & Information Technology Association Conference 2011 (ECTICON 2011), pp.1023-1026.

DOI: 10.1109/ecticon.2011.5948017

Google Scholar

[12] RashmiTurior , Danu Onkaew, Bunyarit Uyyanonvara, Robust Metrics for Retinal Vessel Tortuosity Measurement using Curvature Based on Improved Chain Code , International Conference on Biomedical Engineering (ICBME 2011), pp.217-221, 10-12 December 2011 Manipal, India (December (2011).

DOI: 10.1109/inecce.2011.5953872

Google Scholar

[13] Aslam T, Fleck B, Patton N, Trucco M, Azegrouz H (2009) Digital image analysis of plus disease in retinopathy of prematurity. Acta Ophthalmol 87: 368-377.

DOI: 10.1111/j.1755-3768.2008.01448.x

Google Scholar

[14] W. Lotmar,A. Freiburghaus, and D. Bracher. Measurement of vessel tortuosity on fundus photographs, " Graefe, s Archive for clinical and experimental Ophthalmology, vol. 211, pp.49-57, (1979).

DOI: 10.1007/bf00414653

Google Scholar

[15] E. Bullit, G. Gerig, S. Pizer, W. Lin, and S. Aylward, Measuring tortuosity of the intracerebral vasculature from MRA images, IEEE Trans. Med. Imaging, vol. 22, no. 9, pp.1163-1171, (2003).

DOI: 10.1109/tmi.2003.816964

Google Scholar

[16] Smedby O, Hogman N, Nilsson S, Erikson U, Olsson AG, Walldius G. Two-dimentional tortuosity of the superficial femoral artery in early atherosclerosis,. J Vasc Res 1993; 30: 181-91.

DOI: 10.1159/000158993

Google Scholar

[17] Geoffrey Dougherty and J. Varro, A quantitative index for the measurement of the tortuosity of blood vessels, Medical Engineering & Physics, vol. 22, pp.567-574, (2000).

DOI: 10.1016/s1350-4533(00)00074-6

Google Scholar

[18] M Ramaswamy et al, A Study and Comparison of Automated Techniques for Exudate Detection Using Digital Fundus Images of Human Eye: A Review for Early Identification of Diabetic Retinopathy Int. J. Comp. Tech. Appl., Vol 2 (5), 1503-1516.

Google Scholar

[19] Sanchez, C.I.; Hornero, R.; Lopez, M.I.; Poza, J. Retinal Image Analysis to Detect and Quantify Lesions Associated with Diabetic Retinopathy. In Internat. Conf. on Engineering in Medicine and Biology Society (EMBC), 2004, p.1624 – 1627.

DOI: 10.1109/iembs.2004.1403492

Google Scholar