Short-Circuit Model and Simulation Characteristics of Synchronous Generators

Article Preview

Abstract:

In this paper, the electrical transient mode of synchronous generators is studied, four different simulation model of synchronous generator on sudden short circuit was built, various physical quantities were studied by simulation during the short circuit. By comparing theoretics with simulation, various physical quantities of synchronous generator produced tremendous impact and surge during the sudden circuit and they stabilized in the proceeding state of short circuit. Thoroughly simulation analyzed, the results of simulation are identical with theoretical analysis. The simulation results show that these influence factors should be considered when we design the relay protections.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

709-716

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S. VIJAYALAKSHMI: Modelling and control of a Wind Turbine using Permanent Magnet Synchronous Generator, International Journal of Engineering Science and Technology, Vol. 3 No. 3(March 2011).

Google Scholar

[2] Spoljaric, Zeljko ; Miklosevic, Kresimir & Jerkovic, Vedrana: Synchronous Generator Modeling Using Matlab, information on http: /bib. irb. hr/datoteka/475823. Final_paper-_Spoljaric_Miklosevic_Jerkovic-SIP-2010. pdf.

Google Scholar

[3] M. Shahnazari A. Vahedi: Modeling of Pilot Exciter in Brushless Synchronous Generators Using Average Modeling Approach, 24th international power system conference( 2010).

Google Scholar

[4] Suad Ibrahim Shahl: Synchronous Generators, information on http: /www. uotechnology. edu. iq/dep-eee/lectures/3rd/Electrical/Machines%202/II_SG. pdf.

Google Scholar

[5] Surajit Chattopadhyay, Madhuchhanda Mitra and Samarjit Sengupta: Clarke and Park Transform, Electric Power Quality Power Systems, (2011), pp.89-96.

DOI: 10.1007/978-94-007-0635-4_12

Google Scholar

[6] Park'sTransformation for Space Vector Control, information on http: /www. ee. uidaho. edu/ee/power/EE529/Lectures/L13/session13. pdf.

Google Scholar

[7] Christopher Laughman, Steven Leeb, Leslie Norford, Steven Shaw, Peter Armstrong: A Park Transform-Based Method for Condition Monitoring of Three-Phase Electromechanical Systems, Copyright Mitsubishi Electric Research Laboratories, Inc., (2010).

DOI: 10.1049/cp.2010.0030

Google Scholar

[8] M. Shahnazari, A. Vahedi: Analysis of Brushless Exciter Operation in all Modes of Rotating Rectifier, 4th IEEE Conference on Industrial Electronics and Applications (ICIEA). ( May 2009).

DOI: 10.1109/iciea.2009.5138625

Google Scholar

[9] D. Jolevski: Exitasion System of Synchronous Generator, Faculty of Electrical Engineering, Mechanical Engineering and Naval Architecture, Split, Croatia, preparation for doctoral qualification Exame. (2009).

Google Scholar

[10] Nejjari H, Benbouzid: Monitoring and diagnosis of induction motors electrical faults using a current Park's vector pattern learning approach, IEEE Trans. Ind. Appl. 36, (2000), p.730–735.

DOI: 10.1109/28.845047

Google Scholar

[11] I. Jadric, D. Borojevic, M. Jadric: Modeling and control of a synchronous generator with an active DC load, IEEE Trans. on Energy Conversion, vol. 15, ( March 2000), pp.303-311.

DOI: 10.1109/63.838103

Google Scholar

[12] Liang Zhao: Simulation and Analysis of Short Circuit in 1000MW Synchronous Generator Based on Simulink/SPS Module, Power and Energy Engineering Conference (APPEEC), Asia-Pacific, (March 2010), pp.28-31.

DOI: 10.1109/appeec.2010.5448631

Google Scholar

[13] Chaoxian Han; Xinzhen Wu; Ping Ma: Identification of synchronous generator parameters based on 3-phase sudden short-circuit current. Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2011 4th International Conference, pp.959-962.

DOI: 10.1109/drpt.2011.5994032