Ultrasonic Fatigue Performance of Welded Joints in 16Mn Steel
Abstract:
Ultrasonic fatigue performance test of 16Mn steel and welded joints are carried out by using ultrasonic fatigue test system devices developed by Tianjin University to research its fatigue behavior in the super long life regime. The results show that: regardless of the base mental or welded joints, the S-N curve is a continuous decline curve; Welded joints does not exist the traditional concept of fatigue limit within the range of 106~107, when the number of load cycles exceeds 107 even 109, fatigue fracture still occurs. Within the super long life range, the fatigue strength of welded joint is much lower than the fatigue strength of base mental. It is dangerous to use the existing fatigue data to design the welded structure within the super long life regime.