A Novel Seismic Base Isolation System Consisting of a Lead Rubber Bearing in Series with a Friction Slider. Part II: Application to a Multi-Storey RC Building and Comparison with Traditional Systems

Article Preview

Abstract:

In a parallel paper a new High Damping Hybrid Seismic Isolator (HDHSI) has been proposed and obtained by the assembly in series of a Lead Rubber Bearing (LRB) and a Friction Slider (FS) characterized by a high friction coefficient. In the present paper, within the context of seismic base isolation techniques for the earthquake resistance of Reinforced Concrete (RC) buildings, a multi-storey RC building is analyzed as base isolated by the seismic isolator HDHSI (High Damping Hybrid Seismic Isolator). The seismic response of this base isolated RC building is compared with the seismic response of the same structure isolated by a LRB (Lead Rubber Bearing) isolator. The analysis is developed by considering different seismic events in terms of intensity and in terms of frequency content with regard to a supervening collapse. The purpose of this comparative analysis is to highlight the features offered by the HDHSI system compared to the LRB system in the seismic protection of structures. Accordingly, a nonlinear dynamic analysis is performed for a RC structure base isolated by means of the proposed device. In the analysis anomalous seismic events are considered. They are the El Centro earthquake (N00W component, 1940) which is characterized by high intensity and the Erzincan earthquake (N90W component, 1992) which is characterized by anomalous frequency content. The comparison between the two base isolation systems is presented by analyzing the time history of the shear force and the time history of the displacement at the base of the superstructure. The benefits of the HDHSI system in conferring protection to the structure are shown to be significant even under extreme seismic events.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2174-2184

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Mostaghel, N., Khodaverdian, M., Dynamics of resilient-friction base isolator (R-FBI), Earthquake Engineering & Structural Dynamics, Vol. 15, pp.379-390, (1987).

DOI: 10.1002/eqe.4290150307

Google Scholar

[2] Gueraud, R., Noel-Leroux, J.P., Livolant, M., Michalopoulos, A.P., Seismic isolation using sliding elastomer bearing pads, Nuclear Engineering and Design, Vol. 84, pp.363-377, (1985).

DOI: 10.1016/0029-5493(85)90252-3

Google Scholar

[3] Jangid, R.S., Kelly, J.M., Base isolation for near-fault motions, Earthquake Engineering & Structural Dynamics, Vol. 30, pp.691-707, (2001).

DOI: 10.1002/eqe.31

Google Scholar

[4] NTC 2008, Decreto Ministeriale 14/01/2008, Nuove Norme Tecniche per le Costruzioni, Gazzetta Ufficiale n. 29 del 4 febbraio 2008 - Supplemento Ordinario n. 30, Roma, (2008).

Google Scholar

[5] Cancellara, D., De Angelis, F., Pasquino, V., Displacement based approach for the seismic retrofitting of a RC existing building designed for only gravitational loads, Applied Mechanics and Materials, Vol. 166-169, pp.1718-1729, (2012).

DOI: 10.4028/www.scientific.net/amm.166-169.1718

Google Scholar

[6] Cancellara, D., De Angelis, F., Steel braces in series with hysteretic dampers for reducing the seismic vulnerability of RC existing buildings: assessment and retrofitting with a non-linear model, Applied Mechanics and Materials, Vol. 204-208, pp.2677-2689, (2012).

DOI: 10.4028/www.scientific.net/amm.204-208.2677

Google Scholar

[7] Cancellara, D., De Angelis, A nonlinear analysis for the retrofitting of a RC existing building by increasing the cross sections of the columns and accounting for the influence of the confined concrete, Applied Mechanics and Materials, Vol. 204-208, pp.3604-3616, (2012).

DOI: 10.4028/www.scientific.net/amm.204-208.3604

Google Scholar

[8] Park, Y.J., Wen, Y.K., Ang, A. H-S., Random Vibration of Hysteretic Systems under Bi-Directional Ground Motions, Earthquake Engineering and Structural Dynamics, Vol. 14, pp.543-557, (1986).

DOI: 10.1002/eqe.4290140405

Google Scholar

[9] Nagarajaiah, S., Reinhorn, A.M., Constantinou, M.C., 3D-Basis: Nonlinear Dynamic Analysis of Three-Dimensional Base Isolated Structures: Part II, Technical Report NCEER-91-0005, National Center for Earthquake Engineering Research, Buffalo, N.Y., (1991).

Google Scholar

[10] Mokha, A., Constantinou, M.C., Reinhorn, A.M., Teflon bearings in a seismic base isolation: experimental studies and mathematical modelling, Technical Report No. NCEER-88-0038, National Center for Earthquake Engineering Research, Buffalo, N.Y., (1988).

Google Scholar

[11] Cancellara, D., Pasquino, M., A new passive seismic control device for protection of structures under anomalous seismic events, Applied Mechanics and Materials, Vol. 82, pp.651-656, (2011).

DOI: 10.4028/www.scientific.net/amm.82.651

Google Scholar

[12] Cancellara, D., Pasquino, M., Performance Based Design according to EC8: Fixed-Base vs. Base-Isolated RC frame structures (in Italian), Ingegneria Sismica, Vol. 26 (2), pp.50-61, (2009).

Google Scholar

[13] Cancellara, D., Pasquino, M., Base isolated building with hybrid base isolation system (HDRB & FS in parallel): Linear vs. Nonlinear dynamic analysis (in Italian), Ingegneria Sismica, Vol. 27 (3), pp.17-32, (2010).

Google Scholar

[14] De Angelis, F., An internal variable variational formulation of viscoplasticity, Computer Methods in Applied Mechanics and Engineering, Vol. 190, n. 1-2, pp.35-54, (2000).

DOI: 10.1016/s0045-7825(99)00306-0

Google Scholar

[15] De Angelis, F., A variationally consistent formulation of nonlocal plasticity, Int. Journal for Multiscale Computational Engineering, Vol. 5, n. 2, pp.105-116, (2007).

DOI: 10.1615/intjmultcompeng.v5.i2.40

Google Scholar

[16] De Angelis, F., Multifield potentials and derivation of extremum principles in rate plasticity, Materials Science Forum, Vol. 539-543, pp.2625-2630, (2007).

DOI: 10.4028/www.scientific.net/msf.539-543.2625

Google Scholar

[17] De Angelis, F., On constitutive relations in non-smooth elasto/viscoplasticity, Advanced Materials Research, Vol. 566, pp.691-698, (2012).

DOI: 10.4028/www.scientific.net/amr.566.691

Google Scholar

[18] De Angelis, F., Evolutive laws and constitutive relations in nonlocal viscoplasticity, Applied Mechanics and Materials, Vol. 152-154, pp.990-996, (2012).

DOI: 10.4028/www.scientific.net/amm.152-154.990

Google Scholar

[19] De Angelis, F., A comparative analysis of linear and nonlinear kinematic hardening rules in computational elastoplasticity, Technische Mechanik, Vol. 32, n. 2-5, pp.164-173, (2012).

Google Scholar

[20] De Angelis, F., Cancellara, D., Constitutive equations for a model of nonlocal plasticity which complies with a nonlocal maximum plastic dissipation principle, Applied Mechanics and Materials, Vol. 217-219, pp.2362-2366, (2012).

DOI: 10.4028/www.scientific.net/amm.217-219.2362

Google Scholar

[21] De Angelis, F., Cancellara, D., A consistent formulation of constitutive relations for a model of nonlocal viscoplasticity, Applied Mechanics and Materials, Vol. 217-219, pp.2367-2372, (2012).

DOI: 10.4028/www.scientific.net/amm.217-219.2367

Google Scholar

[22] De Angelis, F., Computational issues in rate dependent plasticity models, Advanced Materials Research, Vol. 566, pp.70-77, (2012).

DOI: 10.4028/www.scientific.net/amr.566.70

Google Scholar

[23] De Angelis, F., Computational aspects in the elasto/viscoplastic material behavior of solids, Advanced Materials Research, Vol. 567, pp.192-199, (2012).

DOI: 10.4028/www.scientific.net/amr.567.192

Google Scholar

[24] De Angelis, F., Numerical algorithms for J2 viscoplastic models, Advanced Materials Research, Vol. 567, pp.267-274, (2012).

DOI: 10.4028/www.scientific.net/amr.567.267

Google Scholar

[25] De Angelis, F., Cancellara, D., Modano, M., Pasquino, M., The consequence of different loading rates in elasto/viscoplasticity, Procedia Engineering, Vol. 10, pp.2911-2916, (2011).

DOI: 10.1016/j.proeng.2011.04.483

Google Scholar

[26] De Angelis, F., Cancellara, D., Implications due to different loading programs in inelastic materials, Advanced Material Research, Vol. 422, pp.726-733, (2012).

DOI: 10.4028/www.scientific.net/amr.422.726

Google Scholar

[27] De Angelis, F., Cancellara, D., Results of distinct modes of loading procedures in the nonlinear inelastic behavior of solids, Advanced Material Research, Vol. 482-484, pp.1004-1011, (2012).

DOI: 10.4028/www.scientific.net/amr.482-484.1004

Google Scholar

[28] Cancellara, D., De Angelis, F., Seismical protection properties of high damping rubber bearing and lead rubber bearing base isolation systems for multi-storey RC buildings, Applied Mechanics and Materials, Vol. 234, pp.90-95, (2012).

DOI: 10.4028/www.scientific.net/amm.234.90

Google Scholar

[29] Cancellara, D., De Angelis, F., Dynamic nonlinear analysis of an hybrid base isolation system with viscous dampers and friction sliders in parallel, Applied Mechanics and Materials, Vol. 234, pp.96-101, (2012).

DOI: 10.4028/www.scientific.net/amm.234.96

Google Scholar